Stufe a Pellet PELLET STOVES User Manual VENTILATED STOVES Read all instructions carefully before installation, use and maintenance The instruction book is an integral part of the product.
Congratulations! You are now the owner of an Extraflame stove! The Extraflame pellet stove is an ideal heating solution. It utilises the most advanced technology and is manufactured to the highest standards with a contemporary design, allowing you to enjoy the ambience and warmth of a natural flame in complete safety. This manual tells you how to use your stove correctly. Please read the entire manual carefully before using your stove.
Index WARNINGS AND SAFETY DEVICES.......................................................................................................... 7 Chapter 2 WHAT ARE PELLETS?................................................................................................................................. 8 PELLET STORAGE .....................................................................................................................................................................8 PELLET LOAD ................
CURRENT TIME AND DAY SETTINGS ............................................................................................................................. 27 FUNCTIONING CYCLE ......................................................................................................................................................... 27 BASIC INSTRUCTIONS .................................................................................................................................................. 27 LIGHTING.
WARNINGS AND SAFETY DEVICES The stoves produced by our establishment are built with attention to the individual components in a way to protect both the user and the installer from any accidents. It is therefore recommended that after any intervention on the product, authorised staff pay particular attention to the electric connections, especially the stripped parts of the wires. These must not escape from the terminal board in any situation, thus preventing possible contact with the live parts of the wire.
Chapter 2 WHAT ARE PELLETS? Pellets are made by applying very high pressure to sawdust; i.e. the residue of raw timber (without paint) produced by sawmills, carpentry works and other activities involved in processing wood. This type of fuel is completely environmentally friendly, as no binders of any kind are used to keep it compact. In fact, the compactness of the pellets over time is guaranteed by lignin, a natural substance found in the wood itself.
Chapter 3 SAFETY DEVICES WARM AIR BLOWER BREAKDOWN If the blower stops for any reason, the stove automatically shuts down to prevent overheating. FUME EXHAUSTER BREAKDOWN If the exhauster stops, the electronic unit immediately prevents pellet feeding. PELLET FEED MOTOR BREAKDOWN If the motor stops, the stove continues to operate until the minimum cooling level is reached. LIGHTING FAILURE If no flame develops during the lighting stage, the stove display shows “NO ACC”.
Chapter 4 ASSEMBLY AND INSTALLATION INSTRUCTIONS The installation must be in compliance with: UNI 10683 (2005) heat generators fed with wood and other solid fuels: installation. The chimneys have to be in compliance with: UNI 9731 (1990) chimneys: classification based on thermal resistance. EN 13384-1 (2006) chimneys thermal and fluid-dynamics calculation method. UNI 7129 point 4.3.3 Fire Department dispositions, local rules and prescriptions. UNI 1443 (2005) chimneys: general requisites.
Chapter 4 SMOKE EVACUATION SYSTEMS Flue gas exhaust system independent from the appliance constituted by a fitting or smoke channel, chimney or individual flue and chimney cap. FORCED DRAUGHT Air circulation by means of the fan activated by electric motor. NATURAL DRAUGHT Draught which determinates in a chimney/flue for effect of the volume mass difference existing between smoke (hot) and surrounding atmosphere air, without any mechanical intake aid installed inside it or at its peak.
Chapter 4 CONNECTION TO THE SMOKE EVACUATION SYSTEM SMOKE CHANNEL OR CONNECTIONS To mount the smoke channels, non-flammable elements will have to be used, ideal for resisting fuel products and their eventual condensing. The use of flexible metal and asbestos cement pipes to connect the appliances to the flue is forbidden, even for pre-existing smoke channels. There must be continuity between the smoke channel and the flue so that the flue does not lean on the generator.
Chapter 4 It is forbidden to have other air supply channels and pipes for plant engineering, especially if over-sized, transit inside the smoke channels. The mounting of manual draught adjustment devices on forced draught appliances is forbidden.
Chapter 4 Chimney cap wind-proof <3m 3-5% Flue Inspection Inspection figure 4.6 figure 4.7 <3m External pipe insulated 45° 45° Inspection Inspection figure 4.8 14 figure 4.
Chapter 4 APPLIANCE CONNECTION TO THE FLUE AND FUEL PRODUCTS EVACUATION The flue must receive the discharge from only one heat generator. The direct discharge towards closed spaces is forbidden, even with clear sky. The direct discharge of the fuel products must be at roof and the smoke pipe must have the features provided in the “Chimney or individual flue” section.
Chapter 4 CHIMNEY CAPS, DISTANCES AND POSITIONING Distance between Roof Minimum chimney height the ridge and the inclination (measured from outlet) chimney β A (m) H (m) < 1,85 0,50 m over the ridge 15° > 1,85 1,00 m from roof < 1,50 0,50 m over the ridge 30° > 1,50 1,30 m from roof < 1,30 0,50 m over the ridge 45° > 1,30 2,00 m from roof < 1,20 0,50 m over the ridge 60° > 1,20 2,60 m from roof CONNECTION TO EXTERNAL AIR INLETS The appliance must be able to use the necessary air to guarantee regular functi
Chapter 5 DIVINA PLUS DISTRIBUTED HEATING DIVINA PLUS The DIVINA PLUS model is equipped with two pipe outlets situated on the back of the stove that allow the heat produced by the stove to be distributed to other rooms. For this purpose, as you can see in the photo below, we recommend using pipes with the following characteristics: Internal diameter 80 mm Insulated pipes (thermal insulation) The pipe length connected to each opening must not be longer than 2 m.
Chapter 6 COMFORT MAXI INSTALLATION The Maxi Comfort model is supplied with a metal sliding base that enables it to be installed in an existing fireplace. The base allows you to slide out the insert easily for maintenance and cleaning at the end of the year. If you do not already have a fireplace, you can build one using the insert support pedestal (optional kit), which is designed to secure the insert to the floor.
Chapter 6 up to the base, connect the plug to the power socket and set the master switch on position 1: the display should come on. The bottom grill of the insert must stand at least 1 cm above the marble fire top of the facing.
Chapter 6 Adjust the height and angle of the hopper according to the fireplace to be built The bottom grill of the insert must stand at least 1 cm above the marble fire top of the facing. EXTRACTING THE INSERT Maxi Comfort has to be extracted to carry out routine maintenance (cleaning the ash pipe at the end of the year) or special servicing (replacing mechanical parts in the event of damage).
Chapter 6 RECIRCULATION AIR PIPES For the correct functioning, and so as to avoid any possible overheating to the apparatus, it is necessary to create a recirculation of air inside the structure which covers the insert. To guarantee this, it is sufficient to create one or more openings, both in the lower and upper parts of the covering. The measurements to be used are the following: Lower part (cold air entrance) D total minimum surface 550 cm2. Upper part (hot air exit) D total minimum surface 500 cm2.
16 cm 45 cm 10 cm Chapter 6 51.5 cm 8.5 cm 6 cm figure 6.12 5 cm 8.5 cm 5 cm figure 6.
Chapter 6 Warm air of convection It is necessary to let the heat (accumulated inside the casing) go out. It must be done to avoid the superheating of the insert. 5 cm Forced ventilation The tangential fan blows in the room the warm air created in the insert. Room air entrance To allows an air loop, it is necessary to have an air entrance hole. For a better convection if it has to be on the bottom of the apparatus. The air will be taken from the room where the stove is installed. figure 6.
Chapter 6 Air inlet box figure 6.15 Air inlet box figure 6.16 As far as the air inlet box is concerned, there is the possibility to connect the air inlet pipe above the sliding base (see picture above) or under it (see picture below) depending on the needs. All these operations must be carried out by a specialized technician.
Chapter 7 FALO’ 1XLP, FALO’ 1CP AND FALO’ 2CP As you can see in the photograph below, our FALO’ 1XLP, FALO’ 1CP and FALO’ 2CP models are provided with a convenient drawer for pellet feeding, so there is no need to disassemble any part of the stove to refill the pellets. figure 7.1 In the FALO’ 1XLP, FALO’ 1CP and FALO’ 2CP models the position of certain parts has been changed to make access easier. As you can see from the illustration below, the position of the following details has been modified: 1.
Chapter 9 REMOTE CONTROL (OPTIONAL “ROSY“) The heat setting, the room temperature, and automatic start/stop of the stove can be remote controlled. S = Luminous warning light that indicates which keys have been pressed. S Correspondence of display keys with remote control keys P2 P5 P3 P4 1 = p3+p5 2 = p2 3 = p3 4 = p4 5 = p5 figure 9.1 To light the stove, press buttons 3 and 5 at the same time and hold for three seconds (Fig. 21); the stove automatically enters the lighting stage.
Chapter 10 ROOM THERMOSTAT DIGITAL THERMOSTAT (INCLUDED) The stove can control the room temperature by means of a digital thermostat whose function is to lower the heating power to the minimum when a pre-set temperature is reached. 1. When the stove has been started and has entered normal operating mode, a number (e.g. 21°C ) appears on display D1 indicating the room temperature. 2. The thermostat can be set using button 2 or 3.
Chapter 10 Thermostat with open contact D the stove switches off or stays off, and display D1 shows “STBY”. This function can also be suspended temporarily by pressing button 1 for three seconds: If the stove is in “STBY” D phase, the stove remains off. Display D1 shows “STBY”, “OFF” and the current time. If the stove is in “T ON” D phase, the stove switches off. Display D1 shows “T ON”, “OFF” and the current time. To return to using this function, press button 1 again.
Chapter 8 PRODUCT FUNCTIONING CONTROL PANEL REMOTE CONTROL SENSOR D2 D1 figure 8.1 REMOTE CONTROL SENSOR D1 D2 figure 8.2 1 D ON/OFF BUTTON The stove can be turned on and off automatically by pressing button 1. 2-3 D AIR TEMPERATURE SETTING Buttons 2 and 3 are used to adjust the room temperature inside the house. 4-5 D OPERATING POWER Buttons 4 and 5 are used to adjust the heating power and warm air ventilation D1 Display for showing the various messages D2 Display for showing the heat setting.
Chapter 8 CURRENT TIME AND DAY SETTINGS Commands procedure 1. Switch the stove off and on again using the master switch on the back of the stove. 2. The following messages are shown: first, the microchip version (EXTRA_43 or later), then “TIME”, “LI 3”, and “OFF”. 3. Press button 5 when “TIME” is being shown to enter the setting mode. 4. The day of the week (from DAY1 to DAY7) is shown on display D1.Enter the current day using buttons 2 and 3 and confirm with button 5.
Chapter 8 LIGHTING 1. Before proceeding, check to make sure that: the hopper is loaded the combustion chamber is clean the burn pot is clean the front door and the pellet drawer are closed the power outlet is connected the switch on the back of the stove is in position 1 2. Press button 1 for three seconds; display D1 will show the message“AT 08”, with the numbers decreasing every second.
Chapter 8 1. 2. 3. 4. ATTENTION!!! The cover of the pellet container must always be kept closed except when loading fuel The sacks of pellets must be kept at least 1.5 metres away from the stove. The hopper should always be kept at least half full. Before refilling, make sure that the appliance is switched off. SHUTDOWN Press button 1 for three seconds. When the three seconds have elapsed, the stove automatically starts the shutdown stage, cutting off the pellet feed.
Chapter 11 USER PARAMETERS Display D1 OFF 00:00 00:00 OFF 1 00 00:00 00:00 OFF 1 00:00 00:00 OFF 1 Display D1 06:00 22:00 25 20 Display D1 00 Display D1 OFF 00 USER PARAMETERS WEEKLY PROGRAMMER Display D2 Function 0 Start/Stop weekly programmer 1 Time of first switch-on 2 Time of first switch-off 3 Consents for first switch-on/switch-off for the various days 4 Installer parameter 5 Time of second lighting 6 Time of second switch-off 7 Consents for second switch-on/switch-off for the various days 8 Time of
Chapter 11 Parameter Display D2 0 1 2 3 4 5 6 7 8 9 A Adjustment buttons Enable/disenable weekly programmer 2o3 Time of 1st switch-on 2o3 Time of 1st switch-off 2o3 Consents 1st switch-on/off for the various days 2o3 Installer parameter 2o3 Time of 2nd switch-on 2o3 Time of 2nd switch-off 2o3 Consents 2nd switch-on/off for the various days 2o3 Time of 3rd switch-on 2o3 Time of 3rd switch-off 2o3 Consents 3rd switch-on/off for the various days 2o3 Function Display D1 Indication ON/OFF OFF or from 00:00 to
Chapter 11 Press button 5 to confirm and go to the next parameter. Press button 4 to go back to the previous one. Parameter 4 (D2 = 5, D1 =”00”) N.B. This parameter is reserved to the installer and must not be modified. Parameter 5 (D2 = 5 (blinking), D1 =Ex. “15.00”) Press button 2 or 3 to set “15.00”, which corresponds to the switch-on time of the 2nd period. Press button 5 to confirm and go to the next parameter. Press button 4 to go back to the previous one. Parameter 6 (D2 = 6 (blinking), D1 =Ex. “22.
Chapter 11 Note: When the weekly programmer is on, the corresponding LED indicator on the control panel is on (see description of indicator lights). TO DISACTIVATE THE WEEKLY PROGRAMMER, enter the User Parameters by pressing button 3 and holding it, then pressing button 5. Display D2 shows a blinking “0”. Use button 2 or 3 to set “OFF” mode on display D1. Press button 1 to confirm and exit. Manual controls via the front panel or remote control take precedence over any programmed settings.
Chapter 11 Summary table Display D1 06:00 22:00 25°C 20°C Display D2 B C D E Function Start day phase/end night phase Start night phase/end day phase Day phase max. temperature Night phase max. temperature Once this function is active, it is still necessary to light the stove using button 1. When the stove switches off because the maximum temperature has been reached, the message “DOFF” appears on D1.
Chapter 11 The adjustment is made on a percentage basis, and therefore any change of this parameter leads to a proportional variation on all loading speeds of the stove. To access the percentage adjustment of pellet feeding, you have to enter the user programming by pressing button 3, and while keeping it pressed, press button 5. At this point use button 5 to move through the menu until you see “F” blinking on D2.
Chapter 12 STOVE CLEANING ECOLOGICA – COMFORT MAXI Maintenance is necessary to ensure the correct operation of your stove over time. Failure to do so may make the stove unsafe. 1. CLEANING THE BURN POT The burn pot must be cleaned every day. To do so: Remove the burn pot form its compartment and clean the holes using the poker provided (figure 13.1) Remove the ash from the burn pot using a vacuum cleaner. Vacuum the ash deposited in the burn pot compartment 2.
Chapter 12 4. CLEANING THE HEAT EXCHANGER (monthly) The heat exchangers chamber has to be cleaned once a month because the ash residue doesn’t let the stove work properly. To do this, it is necessary to remove the firewall: Remove the brazier from his frame Rotate the door latch of 180° like in (figure 13.7). Take the cast iron and rotate it down. Remove it from the combustion chamber by pulling it. Pay attention to the two lateral cast iron levers.
Chapter 12 BELLA – BELLA LUX – DUCHESSA – DUCHESSA STEEL – CONTESSA – CLEMENTINA – DIVINA – DIVINA STEEL – DIVINA PLUS – TOSCA PLUS CLEANING Maintenance is necessary to ensure the correct operation of your stove over time. Failure to do so may make the stove unsafe. 1. BURN POT CLEANING The burn pot must be cleaned every day. To do so: Remove the burn pot form its compartment and clean the holes using the poker provided (figure 13.
Chapter 12 4. CLEANING THE HEAT EXCHANGER (monthly) The heat exchangers chamber has to be cleaned once a month because the ash residue doesn’t let the stove work properly. To do this, it is necessary to remove the firewall: Remove the brazier from his frame Rotate the door latch of 180° like in picture (figure 13.16). Take the cast iron and rotate it down. Remove it from the combustion chamber by pulling it. Pay attention to the two lateral cast iron levers.
Chapter 12 PULIZIA BABYFIAMMA – PREZIOSA – KAROLINA – ISABELLA – GRAZIOSA – ROSY Maintenance is necessary to ensure the correct operation of your stove over time. Failure to do so may make the stove unsafe. 1. BURN POT CLEANING The burn pot must be cleaned every day. To do so: Remove the burn pot form its compartment and clean the holes using the poker provided (figure 13.19) Remove the ash from the burn pot using a vacuum cleaner Vacuum the ash deposited in the burn pot compartment. figure 12.
Chapter 12 4. CLEANING THE HEAT EXCHANGER (monthly) The heat exchangers chamber has to be cleaned once a month because the ash residue doesn’t let the stove work properly. To do this, it is necessary to remove the firewall: Remove the brazier from his frame Rotate the door latch of 180° like in (figure 13.24). Take the cast iron and rotate it down. Remove it from the combustion chamber by pulling it. Pay attention to the two lateral cast iron levers.
Chapter 12 FALÒ 1XLP – FALÒ 1CP – FALÒ 2CP – ESMERALDA CLEANING Maintenance is necessary to ensure the correct function of your stove over time. Failure to do so may make the device unsafe. 1. CLEANING THE BURN POT The burn pot must be cleaned every day. To do so. Remove the burn pot form its compartment and clean the holes using the poker provided Remove the ash from the burn pot using a vacuum cleaner Vacuum the ash deposited in the burn pot compartment figure 12.27 2.
Chapter 12 5. DOOR, ASH DRAWER AND BURN POT SEALS The seals ensure that the stove is hermetically sealed and consequently that it operates correctly. The seals should be checked periodically and replaced immediately if worn or damaged. These operations must be carried out by an authorized technician. figure 12.31 The seals ensure that the stove is hermetically sealed and consequently that it operates correctly. The seals should be checked periodically and replaced immediately if worn or damaged.
Chapter 12 BURN POT PARTITION Some Extraflame products have a partition fixed to the burn pot by a screw, which reduces the amount of carbon monoxide produced by the stove. figure 12.33 figure 12.34 Burn pot of: Bella – Bella Lux – Contessa – Duchessa – Divina – Divina Plus – Falò 1CP – Falò 2CP – Falò 1XLP – Irina Burn pot of: Babyfiamma – Preziosa – Karolina – Isabella – Graziosa – Rosy Removing the burn pot partition can jeopardise stove safety and immediately voids the warranty.
Chapter 13 TABLE OF DISPLAY MESSAGES INDICATIONS Message Display Cause ATTE An attempt is made to switch on a stove again when it has just been shut down (normal shutdown or caused by an alarm situation). HOT Room thermostat set at maximum value. LOU Room thermostat set at minimum value. T ON An external thermostat has been connected. The room thermostat probe is disconnected. The room thermostat probe is interrupted. STBY The stove is off and on standby to be re-started.
Chapter 13 ALARMS Message Display FUM FAIL FUMI TC HIGH TEMP DEPR FAIL NO ACC NO ACC BLAC OUT NO PELL ATTE + ALLARME Cause Solution This indicator lights up when one of the alarms described below is in progress and is accompanied by the corresponding Indicates the presence of an alarm. indication on display D1. To reset the alarm, press button 1 and hold for three seconds when the stove is completely cold.
Chapter 13 INDICATOR LIGHTS LED indicator light Meaning Description Weekly Programmer function. It is switched on when the weekly programmer is active. For all settings relating to the following function, see “Weekly programmer” paragraph. “Room Thermostat” function. This LED is on/off when the room temperature is lower/higher than the temperature set. To modify the temperature setting, use buttons 2 and 3 during normal operation. “Day/Night Temperature” function.
Chapter 14 WARRANTY CONDITIONS EXTRAFLAME S.p.A., with offices in via dell’Artigiananto 10 Montecchio Precalcino (VI), warrants this product for 2 (two) YEARS from purchase date for manufacturer and material faults. The warranty becomes void in case the defect of conformity is not filed with the dealer within two months from date of its finding. The responsibility of EXTRAFLAME S.p.A.
Chapter 14 All particulars subject to normal wear are not covered by warranty: This category includes: • The gaskets, all ceramic or toughened glass, coverings and cast iron or Ironker grids, the painted, chrome or gold-plated details, the majolica, the handles and the electric cables. • Colour variations, crackles and slight size differences of the majolica parts are not a reason for claims, as they are natural features of the materials themselves.
etichetta codice a barre 53
Chapter 16 Notes 54
Chapter 16 Notes 55
Stufe a Pellet EXTRAFLAME S.p.A. Via Dell’Artigianato, 10 36030 MONTECCHIO PRECALCINO Vicenza - ITALY Tel. 0445/865911 Fax 0445/865912 http://www.lanordica-extraflame.com E-mail: info@extraflame.com This document is available at www.extraflame.