User manual

2 SDL720-en-GB_V1.0 12/16
Introduction
CongratulationsonyourpurchaseoftheExtechSDL720PressureManometer.Thisdevice
measuresgaugeanddifferentialpressureintherangeof±29psi.Supportedmeasurementunits
arebar,psi,Kg/cm
2
,mmHg,inchHg,metersofH
2
O,inchesofH
2
O,atmosphere,hPA,andkPA.
LoggeddatareadingsarestoredonanSDcardfortransfertoaPC.Thismeterisshippedfully
testedandcalibratedand,withproperuse,willprovideyearsofreliableservice.Pleasevisitour
website(www.extech.com)tocheckforthelatestversionofthisUser
Manual,other
Translationsofthismanual,andCustomerSupport.
Safety
InternationalSafetySymbols
Thissymbol,adjacenttoanothersymbolorterminal,indicatestheusermustrefertothe
manualforfurtherinformation.
MeterDescription
1. P1Input(positive+)
2. P2Input(negative‐)
3. LCDDisplay
4. HOLDandBacklight
key
5. MAXMINkey
6. SETandClock
key
7. RS232outputjack
8. Resetbutton
9. PowerAdaptorjack
10. SDcardslot
11. ENTERandLOGkey
12. Downarrowkey
(Press&keyatsametimetozerometer)
13. Uparrow/UNITkey
(Press&keyatsametime
tozerometer)
14. PowerONOFF
key
Notes:Items7,8,and9arelocatedbehindthesnapoffcompartmentcoveronmeter’srightside.
Batterycompa rtmen t,tiltstand,andtripodmount arelocatedontherearoftheinstrument.
1
11
12
13
14
2
3
4
5
6
7
8
9
10