User Manual
SD200-EU-EN-V1.2-7/10
6
Advanced Settings
The SET function is used to:
• Format the SD memory card
• Set the date and time
• Set the sampling time
• Set the beeper sound ON/OFF
• Set the SD card Decimal character
• Select the Temperature units
• Set the RS232 data output ON/OFF
1. Press and Hold the SET button for >2 seconds to enter the setting mode. The first
function (Sd F) will appear in the display. Press the SET button to step through the
seven functions. Use the ▲ and ▼ buttons to adjust the selected function. Use the
“LOGGER” button to step through fields within a function. In the SET mode, if no
button is pressed within 5 seconds the logger will revert back to the standard mode.
2. Sd F – Format the SD card. Press the ▲ button to select yES or no. For yES, press
the Enter button to format the card and erase all existing data.
3. dAtE – Set the date and time. Press the ▲ or ▼ buttons to adjust the selected
(blinking) field. Press the Enter button to store the value and to step through the
various fields.\
4. SP-t – Set the sample rate. Press the ▲ button to select the desired sample rate and
press Enter to store the selection. The selections are: 5, 10, 30, 60, 120, 300, 600
seconds and AUTO. In AUTO, the data will be stored every time there is a
temperature change of >1 degree.
5. bEEP - Set the beeper ON or OFF. Press the ▲ button to select ON or OFF and
press Enter to store the selection.
6. dEC - Set the SD card Decimal character. Press the ▲ button to select USA
(decimal) or Euro (comma) and press Enter to store the selection.
7. t-CF - Set the Temp. unit to °F or °C
8. rS232 - Set the RS232 data output ON/OFF. Press the ▲ button to select ON or off
and press Enter to store the selection
9. ESC – Exit the setting mode. Press the SET button to return to normal operation.
System RESET
If a condition appears where the CPU does not respond to keystrokes or the meter seems
frozen, press the RESET button on the side of the datalogger (use a paper clip or similar
pointed object) to return the meter to a working state.
RS232 Interface
A serial output is provided to link the meter to a PC’s serial port. Call Technical Assistance
for more information on this interface.