Specifications
Function Range Resolution Accuracy
DC Voltage
(V DC)
4V 0.001V
±(1.2% reading + 2 digits)
40V 0.01V
400V 0.1V
600V 1V
±(1.5% reading + 2 digits)
AC Voltage
(V AC)
(50 / 60Hz)
400mV* 0.1mV
±(1.5% reading + 15 digits)
4V 0.001V
±(1.2% reading + 3 digits)
40V 0.01V
±(1.5% reading + 3 digits)
400V 0.1V
600V 1V
±(2.0% reading + 4 digits
*400mV range is not autoranging
DC Current
(A DC)
400µA 0.1µA ±(1.0% reading + 3 digits)
4000µA 1µA
±(1.5% reading + 3 digits)
40mA 0.01mA
400mA 0.1mA
10A 0.01A
±(2.5% reading + 5 digits)
AC Current
(A AC)
400µA 0.1µA ±(1.5% reading + 5 digits)
4000µA 1µA
±(1.8% reading + 5 digits)
40mA 0.01mA
400mA 0.1mA
10A 0.01A
±(3.0% reading + 7 digits)
Resistance
400Ω 0.1Ω ±(1.2% reading + 4 digits)
4kΩ 1Ω ±(1.0% reading + 2 digits)
40kΩ 0.01kΩ
±(1.2% reading + 2 digits)
400kΩ 0.1kΩ
4MΩ 0.001MΩ
40MΩ 0.01MΩ ±(2.0% reading + 3 digits)
Capacitance
40nF 0.01nF
±
(5.0% reading + 30 digits)
400nF
0.1nF
±(3.0% reading + 5 digits)
4
µ
F
0.001
µ
F
40
µ
F
0.01
µ
F
100µF 0.1µF ±(5.0% reading + 5 digits)
Duty Cycle
0.1 to 99.9%
0.1%
±(1.2% reading + 2 digits)
pulse width range: 100µs - 100ms (Frequency: 5Hz to 150kHz)
Temp (type-K)
-4 to 1400°F
1°F
±(3.0% reading + 9°F/5°C)
(probe accuracy not included)
-20 to 750°C
1°C