Specifications
GeneralSpecifications
Display 6000countLCDwithmultifunctionindicators
Fullscale6200countsforCapacitancefunction
Fullscale9999countsforFrequencyfunction
LEDlamp ForNonContactVoltageDetector
Functions Current(ACA,DCA),Voltage(VAC,VDC),Resistance,
Capacitance,Frequency,NonContactVoltagedetector,
Continuity,andDiodetest
Polarity indicatesnegativepolarity(positivepolarityassumed)
Currentsensor Halleffect
Overloadindication O.L
DCAzeroadjust MA63:OnetouchZERObutton(alsousedasaRelative
function);MA61:RELbutton(Relative)
Displayrate 2~3readings/second
Battery Two1.5VAAAbatteries
Operatingtemperature 32
0
Fto104
0
F(0
0
Cto40
0
C)
OperatingHumidity <75%RH32
0
Fto86
0
F(0~30C)
<50%RH86
0
Fto104
0
F(30~40C)
Storagetemperature 14
0
Fto122
0
F(10
0
Cto50
0
C)
Altitude 6562’(2000m)
Powerconsumption 20mADCapprox.
Weight 6.0oz.(170g)includingbattery
Dimensions 6.9x2.4x1.3”(175x60x33.5mm)(HxWxD)
Jawopening 0.7(”17mm)3000MCM
Standards IEC/EN610101,EN610102033,EN610102032;CategoryIII
300V,CategoryII600V;pollutionclass2
Electromagnetic
compatibility
<1V/mRFfield:Overallaccuracy= specifiedaccuracy+5%of
therange.Unspecifiedindicationfor1V/mRFfield.
TestLeads UseonlytestprobesratedCATII600V,CATIII300Vorbetter
thatmeettherequirementsofIEC61010031