User manual
MA61_MA63-en-US_V1.0 3/15
14
Zero/RelativeMeasurements
1. PressZERO(MA63)orREL(MA61)toenterthemode.ThedisplaywillshowtheZEROicon.
2. NoweachtimetheZERO/RELbuttonispressedthepresentmeasurementwillzeroandthe
beeperwillsound.ThismodeisespeciallyusefulforDCAmeasurementzeroing.
3. Inthismode,all
subsequentmeasurementsaredisplayedwithrespecttothereference
measurement.Forexample,ifa20Vreadingiszeroedanda30Vreadingissubsequently
measured,theLCDwilldisplay10V.
4. UsetheRELbutton(MA61)ortheZERObutton (MA63)especiallyforlowcapacitance
measurements<1µFforRelativemeasurementsandDCAmeasurements.
5. Toreturntonormaloperation,pressandholdtheZEROorRELbuttonuntiltheZERO
displayiconswitchesOFF.
BatteryReplacement
CAUTION:Pleasedisconnectthetestleadsfromthemeter,turnthemeteroff,andunclampthe
meterfromanyconductorsbeforeattemptingtochangethebatteries.
1. Whenthelowbatterysymbol appearsontheLCD,thebatteriesmustbereplaced.
2. Turnthemeteroffandremovetherearbatterycompartmentscrew.
3. Liftoffthebatterycompartmentcoverandreplacethetwo1.5VAAAcellsobservingcorrect
polarity.
4. Replacethecompartmentcoverandsecure
thescrewbeforeusingthemeter.
NOTES:Pleasedisposeofbatteriesresponsiblyfollowingallvalidlegalstipulations
Followthevalidlegalstipulationsinrespectofthedisposalofthedeviceattheendofits
lifecycle
Cleaning
WiththemeterOFF,useonlyadryclothtowipecleanthemeterhousing.Donotuseharsh
soaps,abrasives,orsolventstocleanthemeterhousing.