Product Manual

MA260enGB_V1.15/15
11
Specifications
ELECTRICALSPECIFICATIONS
Function Range Max.Resolution
Accuracy(ofreading)and
frequencybandwidth
ACCurrent 1.5~200.0AAC 0.1A
±(3.0%+5digits)
50to60Hz
ACVoltage 1.3V~1000V 0.1V
±(0.9%+3digits)
(50Hz60Hz)
±(1.5%+3digits)
(61Hz500Hz)
DCVoltage
+2.1V~1000V
0.1V
±(0.3%+2digits)
0.7V~‐1000V ±(0.3%+2digits)
Resistance 0~10kΩ 1Ω ±(0.9%+2digits)
Diode 0.4V~0.8V 0.1V ±(1.0%+3digits)
VoltDetection 80V~1000VAC n/a 5060Hz
Notes:
Thetimedelaythatresultsfromthemeter’sautomaticsensingcircuit(1to2seconds)may
causeGFCIcircuitstoresetandbreakerstotrip.
ItisnotrecommendedtousecalibrationequipmenttotesttheMA260.Calibratorscanbe
damagedifusedtotesttheMA260.
Accuracyisgivenas±(%ofreading+leastsignificantdigit)at23C±5Cwithrelativehumidity
lowerthan80%.Accuracyisspecifiedforaperiodofoneyearaftercalibration.
ACVandACAspecificationsareforACCoupled,TrueRMS.Fornonsinusoidalwaveforms,
additionalaccuracyCrestFactor(C.F.)considerationsexistasdetailedbelow:
Add3.0%forC.F.1.0~2.0
Add5.0%forC.F.2.0~2.5
Add7.0%forC.F.2.5~3.0
Overloadprotection:AC1000Vrms,DC1000Vforvoltage,resistance,continuity,anddiode
functions.
MaximumOpenVoltageforResistance/Continuitymeasurements:1.6V
Continuitybeeper:Beepersoundswhenresistance
is<25ohmsandisoffwhentheresistance
is>400ohms.Notethatbetween25and400ohmsthebeepermaysound.
MaximumAC/DCoperatingtime:30secondsformeasurements>30VACorDC
ACInputImpedance:>6Kohmsforinputvoltageupto
30VAC.Impedanceincreasesto
approximately420kohmsat1000VAC
AdjacentConductorInfluenceforACAmeasurements:<0.08A/A