PushButtonDescriptions
MomentarypressesoftheMode(M)buttonperformthefunctionsshowninthetable
below.
Fig.34Mode(M)ButtonFunctionTable
SwitchPosition Mode(M)ButtonFunction
ACDC
AC DC
Ω


Momentarilypresstoaccess/exittheRelativemode.Thismodeofoperationisonly
availableforAC/DCvoltage,ACCurrent,andCapacitance.
InDCAmode,presstozerothedisplay;pressandholdtoexitthezero.
Pressandholdthisbuttontoactivate/deactivatetheLCDbacklight.Momentary
pressesswitchDATAHOLDONorOFF.
FunctionSwitchDescription
1. MeterPOWEROFFposition
2. AC/DCCurrentmode(useMbuttontochooseACorDC)
3. AC/DCVoltagemode(useMbuttontochooseACorDC)
4. Capacitance,Continuity,Diode,Resistancemodes
(useMbuttontochoosemode)
5. NonContactVoltageDetectpositionwithalertLED
Fig33MA160FunctionSwitch