Datasheet

PRODUCT DATASHEETPRODUCT DATASHEET
www.extech.com
Specifications subject to change without notice. Copyright © 2015 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form.
Rev. 9/23/15
MA160 True RMS 200A AC/DC
Open Jaw Clamp Meter
Open jaw design provides quick current measurements in
tight locations without breaking the circuit. True RMS provides
accurate readings on noisy, distorted or non-sinusoidal
waveforms. Convenient built-in Non-Contact Voltage (NCV)
Detector allows quick detection of live voltages while the LED
backlight, with two level brightness, and flashlight help take
measurements in dimly lit environment.
Features
0.57" (14.5mm) open jaw size allows current
measurements in tight spaces
Built-in Non-Contact Voltage (NCV) detector with
audible alert and LED indicator
Relative Mode for Capacitance Zero and offset
adjustment
2000 count 2-level backlit LCD display
Convenient LED worklight for viewing in dimly lit area
Continuity and Diode Test
Auto Power Off with disable
Ergomic housing with built-in test lead holders
CAT III-600V rating
Complete with test leads, two AA batteries, and pouch
Ordering
MA160 .............. 200A True RMS AC/DC Open Jaw Clamp Meter
Specifications
Range Basic Accuracy
AC/DC Current 200A (0.1A) ±(2.5%+5d)
AC Voltage 750V (1mV) ±(2.5%+3d)
DC Voltage 1000V (1mV) ±(0.8%+3d)
Non-Contact Voltage (NCV) 100 to 750V
Resistance 60MΩ (0.1Ω) ±(1.0%+2d)
Capacitance 60mF (0.01nF) ±(4.0%+20d)
Continuity /Diode Test Yes
Dimensions 8.3x2.1x1.4" (210x53x35mm)
Weight 5.8oz (164g)
UPC Code: 793950316016