Datasheet
PRODUCT DATASHEETPRODUCT DATASHEET
www.extech.com
Specifications subject to change without notice. Copyright © 2015 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form.
Rev. 9/23/15
MA160 True RMS 200A AC/DC
Open Jaw Clamp Meter
Open jaw design provides quick current measurements in
tight locations without breaking the circuit. True RMS provides
accurate readings on noisy, distorted or non-sinusoidal
waveforms. Convenient built-in Non-Contact Voltage (NCV)
Detector allows quick detection of live voltages while the LED
backlight, with two level brightness, and flashlight help take
measurements in dimly lit environment.
Features
• 0.57" (14.5mm) open jaw size allows current
measurements in tight spaces
• Built-in Non-Contact Voltage (NCV) detector with
audible alert and LED indicator
• Relative Mode for Capacitance Zero and offset
adjustment
• 2000 count 2-level backlit LCD display
• Convenient LED worklight for viewing in dimly lit area
• Continuity and Diode Test
• Auto Power Off with disable
• Ergomic housing with built-in test lead holders
• CAT III-600V rating
• Complete with test leads, two AA batteries, and pouch
Ordering
MA160 .............. 200A True RMS AC/DC Open Jaw Clamp Meter
Specifications
Range Basic Accuracy
AC/DC Current 200A (0.1A) ±(2.5%+5d)
AC Voltage 750V (1mV) ±(2.5%+3d)
DC Voltage 1000V (1mV) ±(0.8%+3d)
Non-Contact Voltage (NCV) 100 to 750V
Resistance 60MΩ (0.1Ω) ±(1.0%+2d)
Capacitance 60mF (0.01nF) ±(4.0%+20d)
Continuity /Diode Test Yes
Dimensions 8.3x2.1x1.4" (210x53x35mm)
Weight 5.8oz (164g)
UPC Code: 793950316016