User manual
EX710-730 –EU_ENG V3.0 4/05
4
Description
Meter Description (Picture of EX730)
1. Current clamp
2. Clamp opening trigger
3. Control buttons:
• Data Hold
• Mode
• Peak
• Backlight
• DCA Zero (EX730 only)
4. Backlit LCD Display
5. COM negative input jack for black test lead
6. Rotary function switch
7. V·Ω·CAP·TEMP·Hz· positive input jack for red
lead
Display icons Description
HOLD Data Hold
Minus sign Negative reading display
0 to 3999 Measurement display digits
DC ZERO DCA Zero (Model EX730 only)
PEAK Peak capture
AUTO Auto Range mode
DC/AC Direct Current / Alternating Current
BAT Low battery
mV or V Milli-volts or Volts (Voltage)
Ω Ohms (Resistance)
A Amperes (Current)
F Farad (Capacitance)
Hz Hertz (Frequency)
o
F and
o
C Fahrenheit and Celsius units (Temperature) (Model EX730 only)
n, m, μ, M, k Unit of measure prefixes: nano, milli, micro, mega, and kilo
•))) Continuity test
Diode test
1
2
3
4
5
6
7