User manual

EX503-EU_ENG V2.1 11/07 13
Specifications
Function Range Resolution Accuracy
400mV 0.1mV
±(0.5% reading + 2 digits)
4V 0.001V
40V 0.01V
400V 0.1V
±(1.2% reading + 2 digits)
DC Voltage
1000V 1V
±(1.5% reading + 2 digits)
400mV 0.1mV
±(2.0% reading + 10 dgts)
4V 0.001V
40V 0.01V
400V 0.1V
±(2.0% reading + 5 dgts)
AC Voltage
1000V 1V
±(2.5% reading + 5 dgts)
400μA 0.1μA ±(1.0% reading + 3 digits)
4000μA 1μA
40mA 0.01mA
400mA 0.1mA
±(1.5% reading + 3 digits)
DC Current
10A 0.01A
±(2.5% reading + 10 digits)
400μA 0.1μA ±(2.5% reading + 10 digits)
4000μA 1μA
40mA 0.01mA
400mA 0.1mA
±(1.8% reading + 5 digits)
AC Current
10A 0.01A
±(3.0% reading + 7 digits)
400Ω 0.1Ω ±(1.2% reading + 4 digits)
4kΩ 0.001kΩ ±(1.0% reading + 2 digits)
40kΩ 0.01kΩ
400kΩ 0.1kΩ
4MΩ 0.001MΩ
±(1.2% reading + 2 digits)
Resistance
40MΩ 0.01MΩ ±(2.0% reading + 3 digits)
40nF 0.01nF
±(5.0% reading + 7 digits)
400nF 0.1nF
4μF 0.001μF
40μF 0.01μF
±(3.0% reading + 5 digits)
Capacitance
100μF 0.1μF ±(5% reading + 5 digits)
5.999Hz 0.001Hz
59.99Hz 0.01Hz
±(1.5% reading + 1 digits)
599.9Hz 0.1Hz
5.999kHz 0.001kHz
59.99kHz 0.01kHz
599.9kHz 0.1kHz
±(1.2% reading + 3 digits)
5.999MHz 0.001MHz
9.999MHz 0.001MHz
±(1.5% reading + 4 digits)
Frequency
Hz% Function
Sensitivity: 0.5V rms <500kHz; 3V rms >500kHz