Specifications
Function Range
Resolution
Accuracy
200mV 0.1mV
±(0.3% reading + 2 digits)
2V 0.001V
200V 0.1V
±(0.5% reading + 2 digits)
DC Voltage
(V DC)
1000V 1V
±(0.8% reading + 2 digits)
50 to 400Hz 400Hz to 1kHz
2V 0.001V
±(1.0% reading +6
digits
±(2.0% reading + 8
digits
200V 0.1V
±(1.5% reading +6
digits
±(2.5% reading +8
digits
AC Voltage
(V AC)
750V 1V
±(2.0% reading +6
digits
±(3.0% reading +8
digits
200μA 0.1μA
200mA 0.1mA
±(1.5% reading + 3 digits)
DC Current
(A DC)
20A 0.01A
±(2.5% reading + 3 digits)
50 to 400Hz 400Hz to 1kHz
200mA 0.1mA
±(1.8% reading +8
digits
±(2.5% reading +10
digits)
AC Current
(A AC)
20A 0.01A
±(3.0% reading +8
digits)
±(3.5% reading +10
digits)
200Ω 0.1Ω ±(0.8% reading +4 digits)
2000Ω 1Ω ±(0.8% reading +2 digits)
20kΩ 0.01kΩ
200kΩ 0.1kΩ
±(1.0% reading +2 digits)
Resistance
20MΩ 0.01MΩ ±(2.0% reading +5 digits)
-20 to
750ºC
1ºF Temperature
-4 to
1382ºF
1ºC
±(3.0% reading +3 digits)
(meter only, probe accuracy not included)
NOTE: Accuracy specifications consist of two elements:
• (% reading) – This is the accuracy of the measurement circuit.
• (+ digits) – This is the accuracy of the analog to digital converter.
NOTE: Accuracy is stated at 18
o
C to 28
o
C (65
o
F to 83
o
F) and less than 75% RH.