Specifications
Function Range Resolution Accuracy
Non-contact AC
Voltage detector
100 to
600VAC
Resolution & accuracy do not apply since the meter does
not display the voltage in this mode. The lamp at the top of
the meter’s display flashes when voltage is sensed and an
audible warning will sound
200mV 0.1mV
±(0.5% reading + 2 digits)
2V 0.001V
20V 0.01V
200V 0.1V
±(1.0% reading + 2 digits)
DC Voltage
(V DC)
600V 1V
±(1.5% reading + 2 digits)
200mV 0.1mV
±(1.0% reading + 30 digits)
2V 0.001mV
20V 0.01V
200V 0.1V
±(1.5% reading + 3 digits)
AC Voltage
(V AC)
(50 / 60Hz)
600V 1V
±(2.0% reading + 4 digits
200μA 0.1μA ±(1.0% reading + 3 digits)
2000μA 1μA
20mA 0.01mA
200mA 0.1mA
±(1.5% reading + 3 digits)
DC Current
(A DC)
10A 0.01A
±(2.5% reading + 5 digits)
200μA 0.1μA ±(1.5% reading + 5 digits)
2000μA 1μA
20mA 0.01mA
200mA 0.1mA
±(1.8% reading + 5 digits)
AC Current
(A AC)
(50 / 60Hz)
10A 0.01A
±(3.0% reading + 7 digits)
200Ω 0.1Ω ±(1.2% reading + 4 digits)
2kΩ 1Ω
20kΩ 0.01kΩ
200kΩ 0.1kΩ
2MΩ 0.001MΩ
±(1.2% reading + 2 digits)
Resistance
20MΩ 0.01MΩ ±(2.0% reading + 3 digits)
NOTES:
Accuracy specifications consist of two elements:
(% reading) – This is the accuracy of the measurement circuit.
(+ digits) – This is the accuracy of the analog to digital converter.
Accuracy is stated at 65
o
F to 83
o
F (18
o
C to 28
o
C) and less than 75% RH.