User Manual
EN100-150-EU-EN v1.1 11/13 13
Humidity/Temperature
Units Range Resolution Accuracy
%RH 10 to 95 %RH 0.1
< 70 %RH :± 4 %RH
≧
70 %RH :± ( 4%rdg + 1.2 %RH )
°F
32 to 122°F 0.1 ± 2.5°F
°C
0 to 50°C 0.1 ± 1.2°C
Dew Point Temperature
Units Range Resolution Accuracy
°F -13.5 to 120.0 0.1
Calculated from %RH and temperature
°C -25.3 to 49.0 0.1
Wet Bulb Temperature
Units Range Resolution Accuracy
°F 22.2 to 120.0 0.1
Calculated from %RH and temperature
°C -5.4 to 49.0 0.1
Wind Chill
Units Range Resolution Accuracy
°F 15.0 to 112.0 0.1 ± 3.6
°C -9.4 to 44.2 0.1 ± 2.0
Heat Index
Units Range Resolution Accuracy
°F 32 to 112.0 0.1 ± 3.6
°C 0 to 100 0.1 ± 2.0
Barometric Pressure
Units Range Resolution Accuracy
hPa
10 to 999.9
1000 to 1100
0.1
1
±1.5 hPa
± 2 hPa
mmHg 7.5 to 825.0 0.1 ± 1.2
inHg 0.29 to 32.48 0.01 ± 0.05