Product Manual

BR200-BR250-EN-V6.2 -7/10
15
Troubleshooting:
Power Reset for the LCD Unit
In the event of a power failure in the BR200/250 LCD display unit,
follow the steps below to perform a power reset:
1. Un-dock the LCD module from the BR200/250 pistol-grip base
unit.
2. Connect the AC adapter to the LCD module and the appropriate
AC power source.
3. Locate the Reset port on the reverse side of the LCD module
(labeled Reset).
4. Momentarily press the Power Reset button for at least 2 seconds
and then release.
5. Leaving the AC adapter connected to the LCD module, power the
unit on.
6. If the unit powers on, allow it to fully re-charge (up to 2 hours)
before removing AC adapter. If the LCD unit does not power on,
repeat steps 1 through 6.
Specifications
CAMERA
Imaging Sensor CMOS
Total Pixels (NTSC) BR200: 712x486 BR250: 640x480
Horizontal View Angle BR200: 50 degree
BR250: 45 degree
Transmission Frequency 2468MHz
Focus point BR200: 8”(20cm), BR250: 6”(15cm)
Minimum Illumination 0 Lux
Modulation Type FM
Bandwidth 18MHz
Power Supply 4 x AA batteries
Unobstructed Effective Range 10m
Waterproof Capacity IP67 (imager head only)