User manual
AN300‐EU‐ENv1.11/13
6
Operation
AirVelocity,Volume,andTemperatureMeasurements
1. SwitchthemeterONbypressingthePOWER buttonmomentarily.PressthePOWER
buttonagaintoswitchthemeterOFF.
2. Notethatthemeterwillautomaticallyenterthesleepmodeafter20minutesofinactivity.
Todisablethisfeature:withthemeterOFF,pressandholdthePOWERandtheU/mode
buttonsfor2seconds.TheLCDwilldisplay'n'asthemeterswitchesON.Nowthesleep
modeisdisabledandtheusermustpressthePOWERbuttonmomentarilytoswitchthe
meterOFF.
3. WhenthemeterisON,theairvelocityreadingisdisplayedontheupperdisplaydigitsin
meterspersecond(m/s)
orfeetperminute(fpm).ThelowerdisplayareacanshowAir
Volume(CMM/CFM)orAirTemperature(°C/°F)readings,usetheL/modebuttontotoggle
betweenthetwo.Notethatanareameasurementmustbeprogrammedintothemeter(in
theSETUPmode)beforeaccuratevolumemeasurementscanbemade.
4. Placethemeter’svaneintheairstream.Theairmustenterthevanefromtherearofthe
meter.Thetemperaturesensorislocatedatthecenterofthevaneontherearofthemeter.
5. ReadthemeasurementdataontheLCD.
6. Tochangebetween
ImperialandMetricunitsofmeasurerefertotheSETUPmodesection.
7. TomeasuretheAirVolumeofaduct,firstmeasuretheduct’sarea(seetheAppendixfor
areacalculations)andthenentertheareavalueinthemeter’sSETUPmodeinin
2
orcm
2
.
Aftertheareavaluehasbeenentered,presstheL/modebuttontoswitchthelowerdisplay
fromAirTemperaturetoAirVolume.Placethemeterintheairstreamtomeasurevolume.
8. Optionally,measureAirVolumewithanairflowconeadaptorbyfirstattachingoneofthe
adaptorsto
themeter(theoptionalconeadaptorkitincludesaroundandasquarecone;kit
partnumberAN300‐C).Themeterwillautomaticallyrecognizetheadaptorandthe‘INSERT
ConeShape’promptwillappearontheLCD(theadaptoriconwillalsoappear).Selectround
orsquareusingthemeter’skeypad.Notethat,regardlessoftheAREAsettingintheSETUP
mode,themeterwilldefaulttothedimensionsoftheattachment(Square:356x346mm
[13.6x13.6”);Round:210mm[8.3”]diameter).NOTE:Ensurethattheairflowadaptoriswell
mountedandlockedbeforetakingmeasurements.
LCDbacklight
PresstheU/modebuttontoswitchONtheLCDbacklight.Thebacklightwillautomaticallyswitch
OFFafterapproximately10secondstoconservebatterypower.Notethatthebacklighting
switchesONautomaticallywhenthemeterisswitchedONbytheuser.