User manual

AN300EUENv1.11/13
11
ErrorMessages
Errorcodesandsolutions
AirTemperature
E02:Temperaturereadingislowerthanthelowrangelimit.Placethemeterinroom
temperaturefor30minutes.IfE02continues,sendtheunittoExtechforrepair.
E03:Temperatureexceedsthehighrangelimit.Placethemeterinroomtemperaturefor30
minutes.IfE03continuestoappear,
sendtheunittoExtechforrepair.
E31:TheAtoDconverterrequiresreplacing.SendthemetertoExtechInstrumentsforrepair.
Airvelocity
E03:Velocityexceedsthehighrangelimit.Testthemeterusinganairvelocitythatisknown
tobewithinthespecifiedrangelimits.SendtheunittoExtechforrepairiftheE03error
messagepersists.
Airvolume
E03:Readingexceedsthemeter’sdisplaylimit.CheckthattheAREAsettingiscorrectinthe
SetupMode.
E04:Airvelocityerror.ReturnthemetertoExtechiftheerrormessagepersists.
OtherErrors
E32:MemoryICerror.Rebootthemeterandcheckitagain;sendittoExtechInstrumentsfor
repairiftheerrormessagepersists.
Nodisplay
1. Checkthatthebatteriesaremakinggoodcontactandarealignedforcorrectpolarity.
2. Replacebatteries.
DisplayswitchesOFFautomatically
Thissymptomcouldbethenormal‘SleepMode’whichswitchesthemeterOFFafter20
minutesofinactivity.Ifthisisnotthe‘SleepMode’,checkwhetherthelowbatteryindicator
appearsbeforetheLCDattemptstoswitchON;ifyes,replacethebatteries.