User Manual

45170 V1.1 5/09
5
Specifications
Range Specifications
Measurement Range Resolution
Accuracy
MPH (Miles per hour) 0.9 to 67.0MPH 0.1MPH
3937 ft/min: ±3% F.S.
> 3937 ft/min: ±4% F.S
km/hr (kilometers per hour) 1.4 to 108.0 km/h 0.1km/h
Knots (nautical miles per hour) 0.8 to 58.3 knots 0.1knots
m/sec (meters per second) 0.4 to 30.0 m/s 0.1 m/s
ft/min (feet per minute) 80 to 5910 ft/min 1ft/min
Temperature/Thermistor 32
to 122
o
F (-0 to 50
o
C) 0.1
o
F/C ± 2.5
o
F (± 1.2
o
C)
Temperature /Thermocouple -148 to 2372°F
-100 to 1300°C
0.1°F
0.1°C
± (1% + 2°F)
± (1% + 1°C)
Relative Humidity 10.0 to 95.0% 0.1% ±4% RH (from 10% to 70%RH)
±4%rdg +1.2% RH (> 70% RH)
Light (Auto Ranging ) 0 to 2,200 Lux 1 Lux
±5% rdg +8 digits
1,800 to 20,000 Lux 10 Lux
0 to 204.0 Fc 0.1 Fc
170 to 1,860 Fc 1 Fc
General Specifications
Display 4 digit (9999 count) Dual Display LCD
Sensors Thin film capacitance humidity sensor
Min/Max Min/Max recalls the highest/lowest reading
Data Hold Data Hold freezes the display
Operating conditions 32 to 122
o
F (0 to 50
o
C) / < 80% RH
Power supply 9 Volt Battery
Dimensions / Weight Instrument: 6.14 x 2.36 x 1.29” (156 x 60 x 33mm)
Vane: 1” ( 24mm ) diameter / 5.7 oz. ( 160 g )
Visit us at www.TestEquipmentDepot.com