SettingtheCurrentTimeandDate
Dateandtimeinformationisstoredwitheachstoredrecordblock.Therefore,itisimportantto
ensurethatthisinformationiscorrect.
1. Press
toswitchOFFthemeter.
2. PressandholdtheDATETIMEbuttonandthenpressthe buttontoswitchONthemeter
toenterthedateandtimesettingmode.
3. Aflashingcursorindicatesthecurrentlyselectedparameter(seconds),usethe▲▼buttons
tosetthecurrentsecond.
4. PresstheDATETIMEbuttontomovetothenextparameter(minutes)andusethe
▲▼buttons
tosetthecurrentminute.
5. Repeatstep4tosetthecurrenthour,day,month,andyear.
6. PressDATETIMEtostorethenewdateandtime,andtoexitthismode.
RecordingData
IntheIntegratingSoundLevelMetermodethemetercanrecordandstoremeasurementdata.
Memorycapacityis32000records whichcanbestoredinupto255blocks.Recordingcanstart
whenintegrationbeginsoratapresettime.Thestoreddatacannotbeviewedonthemeter’s
display;itmustbedownloadedusingthesuppliedPCsoftware.
1. Settingthedatasamplingrate.
a) Pressthe buttontoswitchOFFthemeter.
b) PressandholdtheINTEGTIMEbuttonandthenswitchthemeterON,theIntrsymbol
andthesamplerateinsecondswillbedisplayed.
c) Usethe▲▼buttonstosetthesamplingrate(1to255seconds).
d) PressINTEGTIMEto
storethesettingandexitthismode.
2. Settheintegratingfu nctionsasdescribedpreviousl y.
3. PresstheRECOR DER ASEbuttontoprep areforrecording.TheRECsymbolwillappearonthe
display.
4. Pressthe‖button.ThemeasurementswillstartandtheRECsymbolwillbegintoflash,
indicatingthatdataarebeingstored.
5. Ifintegrationispaused,recordingwillalsopause.
6. Whenthememoryisfilled(32000datapointsor255blocksused),theRECFULLsymbolwill
bedisplayed.