User Manual

Model 382252 Ver. 1.1 08/09
6
Maintenance
Battery Replacement
When the low battery icon '
' appears on the LCD, the meter's batteries must be
changed.
1. Remove power and disconnect the test leads from the meter.
2. Remove the tilt stand from the rear of the meter.
3. Remove the 4 battery compartment screws with a Phillips head
screwdriver.
4. Remove the battery compartment cover and replace the six 1.5V 'AA'
batteries.
5. Affix compartment cover and tighten screw.
6. Reattach the tilt stand.
Cleaning and Storage
Periodically wipe the meter's case with a damp cloth and mild detergent; do not use
abrasives or solvents. If the meter is not to be used for a period longer than 60 days,
remove the batteries and store them separately.
Specifications
General Specifications
Measurements Earth Ground Resistance (in 3 ranges), Earth Voltage,
AC Voltage to 750V and DC Voltage to 1000V
Display Large LCD with dual display
Sampling Time 2.5 times per second
Test lead length Red lead: 50' (15m), Yellow: 33' (10m), Green: 16' (5m)
Over-range indication '1' displayed as most significant digit
Power supply Six 1.5V 'AA' batteries (included)
Low battery indication LCD displays
icon
Auto Power Off After approximately 15minutes of use
Safety EN-61010-1 category III
Weight 24.7oz. (700g) with batteries
Dimensions 7.9 x 3.62 x 2" (200 x 92 x 50 mm)
Supplied accessories Multimeter Test leads (2), Earth Ground test leads (3),
auxiliary earth bars (2), six 'AA' batteries, and carrying case
Operating Conditions 32ºF to 104ºF (0ºC to 40ºC), with < 80% RH
Storage Conditions 14ºF to 140ºF (-10ºC to 60ºC), with < 70% RH