User Manual
2. SPECIFICATIONS
2.1 General Specifications
Display 3-3/4 (4000 count) Digit LCD with 40 segment bargraph
Functions Watts, ACA, DCA, ACV, DCV, Frequency
Polarity “-“ indicates negative polarity
Current sensor Hall effect sensor type
Overload indication Left blinking digit
DCA zero adjust One touch zero key
Display rate 2 readings/second (20 readings/second for bargraph)
Auto Power Off 30 minutes after power ON
Battery Two 1.5V AA batteries
Operating temp. 4
0
F to 122
0
F (-10
0
C to 50
0
C)
Operating Humidity < 85% RH
Power consumption Approximately 10mA DC
Weight 6.7 oz. (190g) including battery
Dimensions 7.2 x 2.5 x 1.4” (183 x 63.6 x 35.6mm) (HWD)
Jaw opening 0.9” (23mm)
Standards IEC 1010 Category III 300V, Category II 600V
2.2 Range Specifications
Function Range Resolution Accuracy Overload protect
40kW 10W ±1.5% ±3dgts See note
Note 50/60Hz, 0-250V, 0-400A, PF 0-1,
Vpeak < 360V
240kW 100W ±1.5% ±3dgts See note
Note 50/60Hz, 0-600V, 0-400A, PF 0-1,
Vpeak < 850V
40kW 10W ±2.5% ±3dgts See note
Note 40Hz – 1KHz, 0-250V, 0-400A, PF 0-1,
Vpeak < 360V
240kW 100W ±2.5% ±3dgts See note
AC Power
Note 40Hz – 1KHz ,0-600V, 0-400A, PF 0-1,
Vpeak < 850V
40kW 10W ±1.5% ±3dgts 0-250V, 0-400A
DC Power
240kW 100W ±1.5% ±3dgts
DC Current
400A 100mA ±1.5% ±3dgts 600A DC
50/60Hz 40 – 1kHZ
AC Current
400A 100mA ±1.5% ±3dgts ±2.5% ±4dgts 600A AC
DC Voltage
400V 0.1V ±1.0% ±2dgts 800V DC
50/60Hz 40 to 200Hz
AC Voltage
600V 1V ±1.5% ±2dgts ±2.0% ±4dgts 800V AC
Frequency
100 to
1000k
0.01Hz ±0.8% ±2dgts Sens. 10V 600V AC