User`s manual

14.2.2 Changing object parameters locally
General
When you change object parameters, all object parameters for the whole image are
changed.
However, in some situations you only want to change an object parameter for one
measurement tool only. The reason for this may be that the measurement tool is in
front of a significantly more reflective surface than other surfaces in the image, or
over an object that is further away than the rest of the objects in the image, and so
on.
Procedure
Follow this procedure:
Place at least one measurement tool in the image.1
Right-click the tool and select Parameters. This will display the following
dialog box.
T638028;a3
2
Select Use local parameters.3
Do one of the following:
Let the program calculate the emissivity. This requires knowledge of the
temperature of the object in question.
Enter a known value for the reflected apparent temperature.
Enter a known value for the distance to the object.
4
NOTE
You can also change an object parameter locally by right-clicking the measurement
result in the results pane.
Using the emissivity calculator requires that Data output is set to Kelvin, Celsius
or Fahrenheit under Options.
Related topics
For in-depth information about parameters, and how to correctly set the emissivity
and reflected apparent temperature, see section 17 – Thermographic measurement
techniques on page 67.
58 Publ. No. T559132 Rev. a449 – ENGLISH (EN) – April 21, 2010
14 Changing settings