User Manual

6RH25EUENv1.05/13
BatteryReplacement
Whenthelowbatteryicon(BAT)appearsontheLCD,theCR2032lithiumbuttonbattery must
bereplaced.Thebatterycompartmentislocatedontherearofthemeter.
1. Useacointoturnthebatterycompartmentcovercounterclockwisetoopen.
2. Notetheposition,orientation,andpolarity
oftheexistingbatteryinstallation.
3. ReplacetheCR2032Lithiumbatteryfollowingthe sameposition,orientation,and
polarity.
4. Replacethebatterycompartmentcoverandsecureitusingacointoturnitclockwise
Neverdisposeofusedbatteriesorrechargeablebatteriesinhouseholdwaste.
As consumers, users are
legally required to take used batteries to appropriate
collection sites, the retail store where the batteries were purchased, or wherever
batteriesaresold.
Disposal: Do not dispose of this instrument in household waste. The user is
obligatedtotake endoflifedevicestoadesignatedcollectionpointforthedisposal
ofelectricalandelectronicequipment.
OtherBatterySafetyReminders
o Neverdisposeofbatteriesinafire.Batteriesmayexplodeorleak.
o Nevermixbatterytypes.Alwaysinstallnewbatteriesofthesametype.
Specifications
Display MultifunctionLCD
Measurementranges
AirTemperature‐20to50
o
C(4to122
o
F)
HeatIndex 46to205
o
C(50.8to401
o
F)
DewPoint 78to50
o
C(108.4to122
o
F)
WetBulb 20to50
o
C(4to122
o
F)
WetBulbGlobe‐25to54.5
o
C(13to130
o
F)
RelativeHumidity 0to99.9%RH
Resolution 0.1
o
C/
o
F/%RH
Accuracy
Temperature ±0.6
o
C(1
o
F)
RelativeHumidity ±3%RH@25
o
Cfrom10to90%RHotherwise±5%RH
Powersupply 1xCR2032LithiumBattery
Dimensions 140x35x18mm(5.5x1.4x0.7")
Weight 50g(1.8oz.)
Copyright©2013FLIRSystems,Inc.
Allrightsreservedincludingtherightofreproductioninwholeorinpartinanyform
www.extech.com