Specifications
General Specifications
Detectable Refrigerants SF6 electrical equipment and gas, HFC, CFC, HCFC refrigerants, HFC
(R134 and R123), halogen gas, ethylene, tetrafluoroethylene,
trichloroethylene, and most compounds containing halogen.
Sensor Replaceable heated diode gas detector (part no. RD200-S)
Accuracy < 2.8g/year (0.1oz./year)
Sensitivity Levels Low 30g/year (1.05oz./year)
High 6g/year (0.2oz./year)
Test Bottle Solution 1:1 ethanol (95%) and distilled water
Warm up Time 2 minutes (approx.)
Response Time Instantaneous
Auto Power OFF Automatic shut off after 10 minutes
Low Battery Indication Battery status LED glows red
Power Supply 9V Battery (rear compartment under protective jacket)
Battery Life 30 hours of normal use
Operating Conditions 0°C to 50°C (32°F to 122°F) <80%RH
Storage Conditions -10°C to 80°C (14°F to 176°F) <70%RH
Length: Flexible Gooseneck only 50.2cm (19.8”)
Length: Gooseneck w/ Sensor 52cm (20.5”)
Meter Dimensions / Weight 185 x 72 x 35mm (7.3 x 2.8 x 1.4”) / 305g (10.8 oz.)
Safety CE; Designed to SAE J1627
Weight
Copyright © 2018 FLIR Systems, Inc.