User`s guide

6
AC & AC+DC CURRENT
Accuracy
MM570 MM560
Range
50Hz to 60Hz
Burden Voltage
500.00µA,
5000.0µA
0.15mV/µA
50.000mA,
500.00mA
3.3mV/mA
5.0000A,
10.000A*
0.5% + 50d 1.0% + 40d
0.03V/A
40Hz to 1kHz
500.00µA,
5000.0µA
0.15mV/µA
50.000mA,
500.00mA
3.3mV/mA
5.0000A,
10.000A*
0.7% + 50d 1.0% + 40d
0.03V/A
1kHz to 10kHz
500.00µA,
5000.0µA
0.15mV/µA
50.000mA,
500.00mA
2.0% + 50d
3.3mV/mA
5.0000A,
10.000A*
Unspecified
Unspecified
0.03V/A
*10A continuous, 20A for 30 seconds max with a 5 minute cool down
interval
TEMPERATURE; T1, T2 DUAL (MM570 ONLY)
Range Accuracy*
-50.0°C TO 1000.0°C
0.3% + 1
o
C
-58.0°F TO 1832.0°F
0.3% + 2
o
F
*Thermocouple range and accuracy not included