Installation manual
Your Triangular WaveTechnologies Deposit Control System is manufactured in the
U.S.A.with premium electronic components. No periodic maintenance is required.The
front panel display indicates the status of the AC Power and Solenoid Coil.These indi-
cators are LEAD’s and will not require replacement.If the indicators are not correct,
c h e ck the AC power and the wire to the solenoid.
For Technical Support contact us at Triangular Wave Technology Inc.
All components of the Triangular Wave Microprocessor Deposit Control Systems are
covered by a Five (5) Year Warranty provided that:
1. No modifications are performed on the unit;
2. The system is installed as recommended byTriangular WaveTechnologies, Inc.and
3. There is no modification or change of installation without prior consultation with
Triangular WaveTechnologies, Inc.or its agents.
In the unlikely event that the unit becomes non-functioning, e.g., the “power”light and/ or
the “coil energized”light are not receiving the signal & are not lit, please return the unit
for replacement to the place of purchase, with proof of purchase information.*
The Triangular Wave System does not affect the potability or the natural mineral content
of the water, as there is no direct contact with the wa t e r.Triangular Wave Te c h n o l o g i e s,
Inc., therefo r e, accepts no responsibility for water quality. .
Triangular WaveTechnologies, Inc. warrants that the Triangular Wave Microprocessor
Deposit Control System will perform as indicated in this Owner’s/ Installation Manual.If
the product does not perform as indicated, the unit may be returned within 90 days from
the invoice date for a refund of the purchase price, less the direct cost of shipping,
installation.* Customer agrees that Triangular WaveTechnologies,Inc.or its agents will
be given access to the equipment for 90 days in order to monitor its performance, if
desired, and/or to inspect the product and installation prior to any requested return
authorization.Under no circumstances shall Triangular WaveTechnologies, Inc.or its
agents be liable for consequential, special, or contingent damages or other claims or
demands in excess of the purchase price of its products. The Deposit Control System is
non-invasive and non-chemical by design, and is suitable for nearly all applications
requiring hard water treatment. The treatment process does not add anything to the
fluid and should not cause damage to piping or equipment. The Deposit Control System
is designed to remove scale;if piping or equipment has suffered corrosion prior to the
installation of a TWT Deposit Control System, the removal of this scale may potentially
reveal cracks/pinholes in this piping or equipment that had been held together by this
scale. If structural damage or corrosion is suspected to exist, appropriate measures
should be taken to alleviate this condition prior to or in conjunction with the installation
of the TWT Deposit Controller. Equipment owners must continue to be responsible in
standard infrastructure and equipment maintenance procedures as recommended by
the manufacturers of all piping and fluid fed equipment.
Triangular Wave Microprocessor Deposit Control System components should be
inspected, upon receipt, for damage that might occur during shipment.The carrier and
Triangular WaveTechnologies, Inc. or its agents must be notified immediately if dam-
age is fo u n d.** With proper care during installation and maintenance, the system will
provide faithful service for many years.
*Triangular Wave Technologies, Inc. or its Authorized Representatives must be notified prior to any return
for the proper Return Authorization, conditions and procedures.
**With the exception of Triangular Wave Technologies, Inc. represented products / components, which are
covered by a separate standard warranty indicated in the products’ Owners Installation Manual provided.
Triangular Wave Technologies,Inc, provides total support before, during, and after the installation.
Product Warranty
Performance Warranty ( 90 Days )
Maintenance
To find out even more about us, and how we can help you, contact us at:
Email: info@triangularwave.com
Bringing You The best in Fluid Management Solutions
Visit Triangular WaveTechnologies, Inc.’s comprehensive website,
the valuable technical resource for all invo l ved in water and fluid
m a n a g e m e n t . . .
WWW.TRIANGULARWAVE.COM
TWT
®
System Packaging Contents
A. TWT Microprocessor Deposit Control Unit
B. Wire for onsite wiring & solenoid coil hookup
C. Hardware kit: Screws, wire ties
D. Controller mounting kit: Mounting brackets & wire ties
E. System registration card
Not Included, Sold Separately:
Contact your dealer and/or TWT, Inc. before installation of system
if application requires a–
• TWT factory wrapped Reaction Chamber
The TWT Reaction Chamber is part of the patented TWT Deposit Control
Technology,the function of which is to control scale and bio-film in the plumb-
ing infrastructure, fixtures, and water-fed appliances found in the facility being
treated. The Reaction Chamber provides a chamber through which the water
flows and is exposed to the triangular wave signal that lies at the heart of the
deposit control technology. As the fluid passes through, it is treated and then
carries that treatment downstream, to condition the rest of the plumbing sys-
tem, non-chemically and reliably.
To use in conjunction with the TWT Deposit Control Systems when required,
Triangular Wave Technologies, Inc. has developed a line of factory-wrapped wire
coil Reaction Chambers to address magnetic pipe environments. Typically, wire
coil cannot be installed on any magnetic pipe, such as steel, galvanized steel,
ductile iron, or cast iron. If a coil is applied to such a pipe, the pipe becomes a
shield and prevents the wave energy from entering the fluid path. The TWT
Reaction Chambers solve this problem by providing an easily installed section of
non-magnetic pipe to provide the proper pipe material for the Deposit Control
System to work as designed. The TWT Reaction Chambers are fully sealed,
protecting their layers of factory-wrapped coil. The PVC, Stainless Steel and the
Industrial Reaction Chamber systems are designed and manufactured to meet
the highest quality specifications.
Testing Equipment & Testing Procedures
Testing the solenoid wrap winding
1:The solenoid coils as illustrated is one continuous spiral of wire.
The continuity may be checked with a VOM meter set to measure
resistance. The solenoid will measure as a short or very low resistance,
a few tenths of an ohm.
2:The solenoid coil must be electrically isolated from the pipe.To test this,
Short both ends of the solenoid together and measure the resistance
from this point to the pipe. The measurement should indicate an open
resistance.
3:The electrical insulation between the solenoid and the pipe should
betested. A test voltage of 600 VAC max may be used.
The impedance/ inductance of the completed solenoid should be
measured:10"pipe:0.9 milli henry +/– 10%
M45