User`s guide
MN15A V1.1 02/09 
2
Introduction 
Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers 
AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity testing plus Type K 
thermocouple temperature measurements. Proper use and care of this meter will provide 
many years of reliable service. 
Safety 
This symbol adjacent to another symbol, terminal or operating device 
indicates that the operator must refer to an explanation in the Operating 
Instructions to avoid personal injury or damage to the meter. 
This WARNING symbol indicates a potentially hazardous situation, which 
if not avoided, could result in death or serious injury. 
This CAUTION symbol indicates a potentially hazardous situation, which 
if not avoided, may result damage to the product. 
This symbol advises the user that the terminal(s) so marked must not be 
connected to a circuit point at which the voltage with respect to earth 
ground exceeds 600V. 
This symbol adjacent to one or more terminals identifies them as being 
associated with ranges that may, in normal use, be subjected to 
particularly hazardous voltages. For maximum safety, the meter and its 
test leads should not be handled when these terminals are energized. 
This symbol indicates that a device is protected throughout by double 
insulation or reinforced insulation. 
SAFETY INSTRUCTIONS 
This meter has been designed for safe use, but must be operated with caution. The rules 
listed below must be carefully followed for safe operation. 
1.  NEVER apply voltage or current to the meter that exceeds the specified maximum: 
Input Protection Limits 
Function Maximum Input 
VDC or VAC  600VAC and VDC 
VDC or VAC 200mV range  200Vrms 
mA AC/DC  200mA 250V fast acting fuse 
A AC/DC  10A 250V fast acting fuse 
(for 30 seconds max. every 15 minutes.) 
Resistance, Continuity  250Vrms for 15 sec. max. 
2.  USE EXTREME CAUTION when working with high voltages. 
3.  DO NOT measure voltage if the voltage on the "COM" input jack exceeds 600V above earth ground. 
4.  NEVER connect the meter leads across a voltage source while the function switch is in the current, 
resistance, or diode mode. Doing so can damage the meter. 
5.  ALWAYS discharge filter capacitors in power supplies and disconnect the power when making resistance 
or diode tests. 
6.  ALWAYS turn off power and disconnect test leads before opening the covers to replace the fuse or battery. 
7.  NEVER operate the meter unless the back cover and the battery and fuse covers are in place and fastened 
securely. 
8.  If the equipment is used in a manner not specified by the manufacturer, the protection provided by the 
equipment may be impaired. 
WARNING 
CAUTION 
MAX 
600V 