User's Guide Mini Digital Multimeter Model MN15A A
Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity testing plus Type K thermocouple temperature measurements. Proper use and care of this meter will provide many years of reliable service. Safety This symbol adjacent to another symbol, terminal or operating device indicates that the operator must refer to an explanation in the Operating Instructions to avoid personal injury or damage to the meter.
Controls and Jacks 1. LCD display 2. Rotary function switch 3. 10 ampere test lead jack 4. Test lead jack for voltage, milliamp, resistance/continuity, diode and temperature functions 5. COM test lead jack 6. Battery compartment (rear) SYMBOLS •))) Continuity Diode AC DC 6 M megga (10 ) (ohms) k -3 m milli (10 ) (volts, amps) kilo (10 ) (ohms) V Volts A Amps Ω Ohms BAT Battery test °C Degrees Celsius °F Degrees Fahrenheit 3 Low battery indicator 3 MN15A V1.
Operating Instructions WARNING: Risk of electrocution. High-voltage circuits, both AC and DC, are very dangerous and should be measured with great care. NOTE: On some low AC and DC voltage ranges, with the test leads not connected to a device, the display may show a random, changing reading. This is normal and is caused by the high-input sensitivity. The reading will stabilize and give a proper measurement when connected to a circuit. AC VOLTAGE MEASUREMENTS WARNING: Risk of Electrocution.
DC CURRENT MEASUREMENTS CAUTION: Do not make current measurements at 10 Amps for longer than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or the test leads. 1. Insert the black test lead banana plug into the negative COM jack. 2. For current measurements up to 200mA, set the function switch to the 200mA position and insert the red test lead banana plug into the mA jack. 3.
RESISTANCE MEASUREMENTS WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements. 1. Set the function switch to the highest Ω position. 2. Insert the black test lead banana plug into the negative COM jack. Insert the red test lead banana plug into the positive Ω jack. 3. Touch the test probe tips across the circuit or part under test. 4. Read the resistance in the display.
BATTERY VOLTAGE TEST CAUTION: Do not measure batteries while they are installed in the devices they are powering. The batteries must be removed from installations before tests can be made. 1. Set the function switch to the 1.5V or 9V BAT switch position. Use the 1.5V position for ‘AAA’, ‘AA’, ‘C’, ‘D’, and other 1.5V batteries. Use the 9V position for square 9V transistor batteries. 2. Insert the black test lead banana plug into the negative COM jack.
Maintenance WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the back cover or the battery or fuse covers. WARNING: To avoid electric shock, do not operate your meter until the battery and fuse covers are in place and fastened securely. This MultiMeter is designed to provide years of dependable service, if the following care instructions are performed: 1. 2. 3. 4. 5. 6. KEEP THE METER DRY. If it gets wet, wipe it off.
Range Specifications Function Range Resolution 200mV 0.1mV Accuracy ±(0.5% reading + 2 digits) 2000mV 1mV 20V 0.01V 200V 0.1V 600V 1V AC Voltage 200V 0.1V (V AC) 600V 1V ±(1.2% reading + 10 digits (50/60Hz) DC Current 200mA 0.1mA ±(1.2% reading + 2 digits) ±(2.0% reading + 2 digits) DC Voltage (V DC) (A DC) Resistance 10mA 0.1Ω 2000Ω 1Ω 20kΩ 0.01kΩ 200kΩ 0.1kΩ 20MΩ 10kΩ 9V 10mV 1.
General Specifications Diode Test Continuity Check Input Impedance AC Bandwidth Display Overrange indication Polarity Measurement Rate Low Battery Indication Battery Fuses Operating Temperature Storage Temperature Operating Humidity Storage Humidity Operating Altitude Weight Size Approvals Safety Bias voltage: 2.
Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website at www.extech.com.