User`s guide
MA220-en-EU_V1.9 8/14
8
Jaw size 23mm (0.9") approx.
Display 4000 count LCD
Continuity Audible tone < 150 approx.
Diode Test Open circuit voltage < 1.5VDC;
Test current 0.3mA (typical)
AC V bandwidth 50Hz to 400Hz
AC A bandwidth 50/60Hz
Low battery indication “ ” is displayed
Overrange indication “OL” is displayed
Auto Power OFF After 30 minutes
Measurement rate 2 per second, nominal
Input Impedance 7.8MΩ (V DC and V AC)
Operating Temperature 5ºC to 40ºC (41ºF to 104ºF)
Storage Temperature -20
o
C to 60
o
C (-4
o
F to 140
o
F)
Operating Humidity Max 80% up to 31ºC (87ºF) decreasing linearly to 50% at 45ºC (113ºF)
Storage Humidity <80%
Operating Altitude 2000 meters (6560ft) operating
Batteries (2) 1.5V AAA batteries
Weight 200g (0.44lb)
Size 200x50x35mm (7.87” x 1.97” x 1.38”)
Safety For indoor use and in accordance with the requirements for double
insulation to IEC1010-1 (1995): EN61010-1 (1995) Overvoltage
Category III 600V, Pollution Degree 2.
Copyright © 2014 Flir System Inc.
All rights reserved including the right of reproduction in whole or in part in any form.
www.extech.com