User Manual

IR267enUS_v1.21/17
8
Sett ingsMode
PressandreleasethetriggerandthenpresstheM(Mode)buttontoaccesstheSettingsMode.
UsetheMbuttontostepthroughsettingslistedbelowandusetheSETbuttontomakechanges.
Displaymode:Maximumreading(MAX),Minimumreading(MIN),Averagereading(AVG),
Differentialreading(DIFF)
BacklightON/OFF(LitE)
Laserpointer(LAS)ON/OFFsetting
HighTemperatureAlarmLimitsetting(ALMH)
LowTemperatureAlarmLimitsetting(ALML)
Emissivity(
)setting
Temperatureunitselection(°C/°F)
BuzzerON/OFF(bU2)
ToexittheSettingsMode,pressthetriggertoreturntonormaloperatingmodeorsimplyallow
theautomaticpowerOFFfeaturetoswitchthemeterOFF.
DisplayMode:MAXMINAVGDIFF
Pressthetriggerandrelease.
UseMButtontostepthroughMAXMINAVGDIFdisplaymode
icons.PressSETwhenthedesire diconisshown.Pullthetriggertoreturntothenormal
operatingmode.Thedisplay(smallerdigitslowerright)willreflecttheselectedmode.
BacklightON/OFF
Pressthetriggerandrelease.
UsetheMbuttontosteptotheLitEdisplay.PresstheSETbutton
toselectoNoroFF.Pullthetriggertoreturntothenormaloperatingmode.
LaserON/OFF
Pullthetriggerandrelease.
UsetheMbuttontosteptotheLASdisplay.UsetheSETbuttonto
selectoNoroFF.Pullthetriggertoreturntothenormaloperatingmode.WhenthelaserisON,
thelasericon willappearontheLCD.
HIGHTemperatureAlarmLimitSetting
Pullthetriggerandrelease.
UsetheMbuttontosteptoAlmH.Usethearrowbuttonstosetthe
HighAlarmlimit.PresstheSETbuttontoturntheHighAlarmOFF.Pullthetriggertoreturnto
thenormaloperatingmode.Ifthehighalarmlimitisexceededwhentakingmeasurements,the
displayedALMHwillblinkandthealarmbuzzerwillsound(ifbU2issettoON).
LOWTemperatureAlarmLimitSetting
Pullthetriggerandrelease.
UsetheMbuttontosteptoAlmL.Usethearrowbuttonstosetthe
LowAlarmlimit.PresstheSETbuttontoturntheLowAlarmOFF.Pullthetriggertoreturntothe
normaloperatingmode.Ifthelowalarmlimitisexceededwhentakingmeasurements,the
displayedALMLwillblink.
EmissivitySetting
Pullthetriggerandrelease.
UsetheMbuttontosteptothe icon.Usethearrowbuttonsto
adjusttheemissivity(in0.01steps).Theemissivityrangeis0.05to1.00.Pullthetriggertoreturn
tothenormaloperatingmode.Formoreinformation,seetheEmissivitysection.