User Manual
EX36x‐en‐GB_V1.61/17
23
Function Range Resolution Accuracy(ofreading) ‘OL’Reading
µAAC(EX363only)
600.0µA 0.1uA ±(1.5%+3digits) 660.0µA
LCDDisplays‘0’countswhenthereading<10counts
InputImpedance:3kΩapprox.
FrequencyResponse:45~500Hz(sinewave)
Overloadprotection:1000VAC/DC
ACCurrent(EX365)
6.000A 0.001
±(1.5%+3digits)
6.600A
10.00A 0.01 20.00A
In6ARange,theLCDdisplays0countswhenthereading<20counts.
In10ARange,theLCDdisplays0countswhenthereading<10counts.
Maximummeasurementtime:>5Aformax.3minuteswithatleast20minutesresttime.
>10Aformax.30secondswithatleast10
minutesresttime.
FrequencyResponse :45~500Hz(SineWave)
OverloadProtection:AC/DC11A
DCCurrent(EX365)
6.000A 0.001
±(1.0%+3digits)
6.600A
10.00A 0.01 20.00A
Maximummeasurementtime: >5Aformax. 3minuteswithatleast20minutesresttime.
>10Aformax.30secondswithatleast10minutesresttime.
OverloadProtection:AC/DC11A
Resistance
600.0Ω 0.1Ω ±(0.9%+5digits) 660.0Ω
6.000kΩ 0.001kΩ
±(0.9%+2 digits)
6.600kΩ
60.00kΩ 0.01kΩ
±(0.9%+2 digits)
66.00kΩ
600.0kΩ 0.1kΩ
±(0.9%+2 digits)
660.0kΩ
6.000MΩ 0.001MΩ
±(0.9%+2 digits)
6.600MΩ
40.00MΩ 0.01MΩ
±(1.5% +5digits)
44.00MΩ
OverloadProtection:1000VAC/D
C
Notethatdigitsmayfluctuate±50digitswhenmeasuringabove10.00M
Continuity
600.0Ω 0.1Ω
±(0.9%+5digits) 660.0Ω
Continuity:Buil
t
‐inbeepersoundswhenmeasuredresistanceislessthan20Ω.Beeperturnsoffwhen
measuredresistancegoesabove200Ω
Continuitybeeperfrequencytone:2KHz;ResponseTime:<500μsec.;OverloadProtection:AC/DC1000V
Diode
1.550V 0.001V
±(0.9%+2digits) n/a
OpenCircuitVoltage:Approx.1.8V;OverloadProtection:AC/DC1000V
Capacitance
1.000µF 0.001µF ±(1.9%+5digits) 1.100µF
10.00µF 0.01µF
±(1.9%+2digits)
11.00µF
100.0µF 0.1µF 110.0µF
1.000mF 0.001mF 1.100mF
10.00mF 0.01mF 11.00mF
OverloadProtection:1000VAC/DC