Specifications
DCP60‐en‐EU_V1.59/14
9
RemoteControlOperation
Therearetwomethodsforremotelycontrollingcurrentandvoltageadjustments.Currentmustbe
controlledforbothmethodsotherwisetheunitwilldefaulttoCCmode.
REMOTECONTROL–METHOD1:UsingtwoexternalDCvoltagesources
RemoteSocketPinAssignmentforexternalvariablevoltagesource
PIN FUNCTIONS REMARKS
1 InternalDC+5V Lowerthan50mA
2 Voltageadjust 0to5V ExternalVDC
3 Currentadjust 0to5VExternalVDC
4 Ground
5 OutputOFF ShorttogroundforOFF
6 N.A.
7 N.A.
8 N.A.
Checktheoutputvoltagerangeofthepowersupplybyvaryingtheexternalvoltagesource.
Shortcircuitthemainoutputwith10AWGwiretochecktheCCsettingonthedisplaywhile
varyingtheexternalvoltagesource.
REMOTECONTROL–METHOD2:Usingtwo0to5KOhmvariableresistors
RemoteSocketPinAssignmentforexternalvariableresistor
PIN FUNCTIONS REMARKS
1 InternalDC+5V Oneendofresistor
2 Voltageadjust Variablelegofresistor
3 Currentadjust Variablelegofresistor
4 Ground Otherendofresistor
5 OutputOFF ShorttogroundforOFF
6 N.A.
7 N.A.
8 N.A.
Checktheoutputvoltagerangeofthepowersupplybyadjustingthe5Kohmvariableresistor.
Shortcircuitthemainoutputwith10AWGwiretochecktheCCsettingonthedisplaywhile
adjustingthevariableresistor.