ControlModeSelections
Therearefourcontrolmodes forthepowersupply:NORMAL,PRESET,SETandREMOTECONTROL
modes.SlidetheModeSelectionSwitch(8)tothedesiredMode.Thepowersupplyisfactory
presettoNormalModewithmaximumcurrentlevelCC.
NormalMode
Thisisthefactorydefaultmode;thepowersupplyoutputVoltageandCurrentarecontrolledby
thedualactiongainknobs.
1. Pushtheknobstotogglethecoarseandfinetuning,noticethesubtlechangesin
brightnessoftherelatedLED.
2. Adjusttheknobstothedesiredvaluesusing
coarseandthenfinetuning.
3. Tocheckthepresetcurrentlevel,turntheCurrentKnoblightlyinanydirection.
4. Thedisplaywillresumeitsnormalbrightnessafterafew
secondstore‐affirmtheadjustment.
Note:Thetotalratedcurrent(Aux.+Main)is10A
PresetMode
1. Inthismode,theRearControlLightisONtoindicatethatthe
panelV&Icontrolsarede‐activated.
2. TherearethreepresetoutputsP1/P2/P3availableusingtheRecallSelectionSwitch(9)
3. Thepresetvaluesarefactorysetasshowninthetablebelow.
4. Theusercanchangetheseoutputsettings;pleaserefertothenextparagraph.
RecallNo. OutputVoltage OutputCurrent
P1 5V Maximum
P2 13.8V Maximum
P3 55V Maximum
SetMode
EntertheSetModebypushingSwitch(8)totheSetModeslot;thepowersupplyisnowreadyto
bepreset.
TodefinethepresetoutputP1/P2/P3
1. MovetheRecallSwitch(9)topositionP1,P2orP3
2. Adjustthefrontpanelvoltagecontrolknobtosetthedesiredvoltagevalue
3. Adjustthefrontpanelcurrentcontrolknobtosetthedesiredcurrentlimitvalue
4. RepeattheprocedurefortheremainingrecalllocationsP1,P2,P3ifdesired.
5. MoveModeSwitch(8)fromSettoPresetpositiontoconfirmthesettings.
SetModeNotes:
Allpresetsaresavedafterthepowersupplyhasbeenswitchedoff.Alwayschecktheoutput
voltageofthePresetbeforeconnectingtoaLoad.Tocheckthepresetvalues:
1. MovetheModeSwitch
(8)tothePresetpositionandthensettheRecallSwitch(9)toP1,
P2orP3.
2. TheVandIsettingsforthecorrespondingRECALLP1,P2,P3memorieswillbeshownon
thepanelmeter.
8
9