MSDS
Technical Specification
2010 / 04 / 15
GP001-392A-03 4 - 11
8. Safety Characteristics
Item
Condition
Period
Requirements
Acceptance
Standard
Short circuit
Characteristics
Temp.: 20 ±2°C 24 hrs
There shall be no
explosion of battery
N=9, Ac=0, Re=1
9. Marking
The following markings will be printed, stamped or impressed on the body of the battery:
:
1) Designation 392A
2) Manufacturer's name or abbreviation “Golden Power Logo”
3) Polarity Marking
Marking ‘392A+ BUTTON CELL’
Location On cathode can
10. Caution for Use
1. Since the battery is not manufactured for recharging, there are risks of electrolyte leakage
or causing damage to the device if the battery is charged.
2. The battery shall be installed with its "+" and "-" polarity in correct position, otherwise may
cause short-circuit.
3. Short-circuiting, heating, disposing of into fire and disassembling the battery are
prohibited.
4. Battery cannot be forced discharge, which lead to excess internal gas generation and,
may result in bulging, leakage and de-crimping of cap.
5. New and used batteries cannot be used at the same time, when replaced batteries
recommend to replace all and with the same brand type.
6. Exhausted batteries should be removed from compartment to prevent over-discharge,
which cause leakage & damage to the device.
7. Direct soldering is not allowed, which will damage the battery.
8. Battery should be kept out of the reach of children to prevent swallow, in case of accident
should contact physician at once.
9. The battery should not be dismantled and deformed.