Specifications

A Principled Technologies report 9
Workstation heat, sound, and power usage: Lenovo
ThinkStation S30 vs. HP Z420 Workstation
APPENDIX B: DETAILED TEST METHODOLOGY
Measuring surface temperature
Test requirements
Fluke® 2680A Data Acquisition System
PassMark BurnInTest Professional
Linpack benchmark
Measuring system temperature and power while idle
Setting up the test
1. Set the power plan to the manufacturer’s default setting. Set the display brightness to 100 percent:
a. Click Start.
b. In the Start menu’s quick search field, type Power Options
c. Move the Screen brightness slider all the way to the right.
2. Set the remaining power plan settings as follows:
Dim the display: Never
Turn off the display: Never
Put the computer to sleep: Never
3. Disable the screen saver.
4. Place the workstation, mouse, keyboard, and display in a windowless, climate-controlled room.
5. Attach a Type T thermocouple to the exterior of the workstation at the following locations:
Front center
Top
Side opposite the motherboard
Side closest to the motherboard
Back in center of power supply exhaust
6. Attach a Type T thermocouple to the following locations inside the case:
On the hard drive
On the CPU heatsink
On the VRM FET
On the chipset heatsink
On one DIMM
7. Close the case.
8. Configure the Fluke 2680A Data Acquisition System to take measurements from the temperature
probes and one ambient temperature probe using the Fluke DAQ software.
a. Connect the Type T thermocouples to channels in the Fluke Fast Analog Input module (FAI).
b. In the Fluke DAQ software, click each surface temperature channel, select Thermocouple from
the list of Functions, and choose T from the list of ranges.
c. Label each channel with the location associated with each thermocouple.
d. In the Fluke DAQ software, click the ambient temperature channel, select Thermocouple from
the list of Functions, and choose T from the list of ranges.
e. Label this channel Ambient.
9. While running each test, use a Fluke 2680A Data Acquisition System to monitor ambient and
temperature at each interior and exterior point.