User`s manual
DC and AC Voltage Measurements
1. Set the Function Switch to the V position.
2. Press the AC/DC key (directly below the HOLD key) to select AC or DC Voltage. The meter will
show the selection with an AC or DC symbol (upper left side of LCD).
3. Insert the black test lead to the COM input jack and the red test lead to the V jack.
4. Connect the test leads in PARALLEL with the circuit to be measured.
5. Read the measured value from the LCD display.
Resistance and Continuity Measurements
CAUTION: Before taking any in-circuit resistance measurements, remove power from the circuit under
test and discharge all capacitors.
1. Set the Function switch to the Ω position.
2. Insert the black test lead to the COM input jack and the red test lead to the Ω input jack.
3. Connect test leads to the device to be measured.
4. Read the measured value from the LCD display.
5. If the resistance is < 40Ω (approx.) an audible signal will be heard.