User’s Guide Digital Stopwatch Model 365535
Instructions Introduction You are about to enjoy an advanced Cumulative and Lap memory professional digital quartz stopwatch with advanced timing features. General Features -4 buttons operation -Large LCD display with contrast adjustment -12/24 hour display -Normal time and chime -Daily alarm -Full 1/100 second chronograph with working range from 0 to 19 hr. 59 min. 59.99 seconds with 500 memory records of split and lap time.
As you choose each "mode", a message will be displayed for a second before you enter the mode: Normal Time mode TIME Timer Mode TIMER Alarm Time mode ALARM Pacer mode PACER Chronograph mode Lap Time Recall mode Data mode CHRONO Stroke Measurement STROKE RECALL DATA The operation of the stopwatch is divided into eight modes (as noted above): 1. 2. 3. 4. 5. 6. 7.
This is only a brief description of these buttons. Detailed uses of the buttons are different in particular functions and will be described later in the instructions. Pressing [MODE] button will toggle among the modes above. Note that there is no auto-return function in the stopwatch.
or date-month (d-m), Sound ON or OFF, Contrast (darkness of the digits - default is 9), then back to Second, and recycles again. Note: when the second is to be set, press [START] to reset the second digits to zero. At the end of setting, press [RECALL] or [MODE] to exit from the setting mode and back to Normal Time Display. Display for Sound ON or OFF setting : (Let the current status be "ON".
Alarm Time Mode Press [MODE] until you enter Alarm mode. This mode is used for displaying the daily alarm time and allows you to enable or disable the alarm. When you enter the Alarm Time mode, the display shows the alarm time on the upper line while the date is shown in the middle of the display and the normal time is on the lower line. AL TU A P 3:30 1-3 10”35’30 To toggle the alarm ON or OFF, press [RESET].
Whenever the stopwatch stops running, the "STOP" indicator will be ON. Press the button [START/STOP] to start the stopwatch. As it runs, the current elapsed time is shown on the lower line. {000} SPLIT LAP RUN 0:00’00”00 0:00’00”00 0:03’35”52 To view the current split / lap time, you can press [LAP/SPLIT]. {1} SPLIT LAP RUN 0:10’43”35 0:10’43”35 0:10’43”35 The number of split/lap times is shown on the upper left corner. The corresponding split and lap times are displayed on the upper and middle line.
displayed. The icon "FULL" will be steadily ON. The maximum memory counter value is 100, 300 or 500. To stop the chronograph, press [STOP]. The indicator "STOP" will come on again to show the status. Press [RESET] as the stopwatch stops to reset the stopwatch while the split/lap times will be kept in memory. When the stopwatch starts running from reset state, all the lap memories will be cleared. Decimal Timing 1.
Go to the 1/10,000 hour chronograph by pressing [LAP/SPLIT] again.(1/10,000H) {000} SPLIT LAP STOP 0:00’00”00 0:00’00”00 0:00’00”00 1/1000M Please note that if the stopwatch has started running (or is running), no selection for chronograph operating modes can be made until the stopwatch has been stopped and reset.
Then comes the slowest lap time by further pressing of [RECALL]. RECALL SLOW {001} 0:00’07”63 0:00’07”63 0:03’10”16 SPLIT LAP STOP 1/100000H Press [RECALL] again to view the average lap time. RECALL AVG {005} SPLIT LAP RUN 0:00’05”12 0:03’16”03 Press [RECALL] continually to review all the stored split/lap times. The sequence starts from the last record to the first record when the stopwatch is running and vice versa when the stopwatch has been stopped.
[RECALL] {002} SPLIT LAP RUN [RECALL] {1} SPLIT LAP RUN 0:00’09”48 0:00’01”85 0:03’45”34 0:00’07”63 0:00’07”63 0:03’48”01 After recalling the first record, press [RECALL] once more to exit from Recall mode and go back to chronograph mode. The "RECALL" icon will be OFF. [RECALL] {005} 0:03’50”11 SPLIT 0:00’42”60 LAP 0:03’50”11 RUN During memory recall, you can press either [START], [STOP] or [LAP/SPLIT] to exit from chrono recall mode and jump to the chrono start/stop or lap state respectively.
You can press [START] to scroll through all segments. The current segment will come first. {008} SEG {2} 2001 2-19 A 10:15’30 The header consisting of the date/time stamp will be shown. The number of laps in the segment will appear in the upper left while the segment number is displayed in the middle left. If the segment shown is not your desired segment, press [START] to reach the desired segment. The current segment will be accessed first, then it will cycle back to the 1st, then 2nd and so on.
A ready period of 2 seconds will be counted. At the end of the ready period, a ll the lap records of the corresponding segment will be erased. And a long beep sound will be heard. Then the display will show the next segment. If you don't want to delete the records, you can press any key to exit from delete ready state b e f o r e t h e e n d o f t h e r e a d y p e r i o d a n d r e s u me t h e d i sp l a y o f t h e s e g me n t f r o n t p a g e .
Before starting the timer, enter a countdown time first. Then press [START] to start timer running. When the timer counts down to zero, a 3 second beep ... beep sound will be generated for a timer setting within one minute; 15 second beep ... beep sound for 1 minute to 10 minutes setting and 30 second beep ... beep sound for over 10 minutes. Pressing any key will stop the beep sound. Under CR operation mode, the timer value will be reloaded and count down will start again.
Press [RESET] again to adjust the operating mode. Press [START] to switch the operating modes among CR, CS and CU. {000} CR 0:00’00”0 0:00’00”0 A 12:59’11 At the end of setting, press [RECALL] or [MODE] to leave setting mode Pacer Mode Press [MODE] until you enter the Pacer mode.
Stroke Measurement Press [MODE] until you enter the Stroke Measurement mode. The display will be as follows. STROkE 0.0 In the Stroke Measurement mode, the duration of 3 strokes is taken and the stroke frequency (counts per minute) is calculated. As the stroke frequency falls out of the range of 10 - 180, "Err" will appear to show the error condition. Press [START] to start the measurement. During the 1st second, 180.0 will be shown and flashing as below. STROkE 180.