Specifications

STEP 1 - SELECT LINK
1-1) Press to enter the MAIN MENU.MENU
1
F1
F3
F1 DONE
F2 DONE
DONE
F2
2
1
F2
DONE
DONE
DONE
F1 DONE
1-2) Press to SELECT LINK.
1-3) At the STORED LINKS menu, the currently loaded link is denoted by an asterisk. Scroll through the list of links by pressing
to highlight the link to use. Press to edit the name and the testing date of the selected link.
EDIT LINK
1-3a) Give the link a descriptive name. Press to edit the name. Press to continue.
1-3b) Enter the date of the test. Press to enter the date. Press to continue.
1-3c) When the name and date have been entered, press to return to the STORED LINKS menu.
1-4) Press to load the selected link. The user will be returned to the MAIN MENU.
STEP 2 - DEFINE LINK
2-1) Press to DEFINE LINK.
2-2) Press to CERTIFY LINK.
2-3) Scroll through the list of fiber types and highlight the link’s fiber type. Press to select.
2-4) Enter the length of the fiber in meters. Press to continue.
2-5) Enter the number of inline connections (connector pairs) in the link. Press to continue.
2-6) Enter the number of inline splices in the link. Press to continue.
2-7) Connect the light source for the wavelength shown on the display (remember: if the user is testing multi-mode fibers, the test
jumper must be wrapped 5-7 times around a mandrel). Press or to continue.
2-8) The settings the user just entered will appear on the display (see the example below).
SRC PWR (shown in dBm) - actual power the light source is emitting.
100 m (shown in dB) - attenuation value associated with the length and type of fiber the user entered.
0 CONN (shown in dB) - attenuation value of the connectors and splices the user entered.
REF PWR (dBm) - source power plus fiber attenuation plus connector and splice attenuation. This is the PASS / FAIL
threshold.
850nm - wavelength that the reference is being set for.
M6 - fiber type that the reference is being set for (M6 = 62.5 µm multi-mode, M5 = 50µm multi-
mode, SI = single mode indoor, SO = single mode outdoor).
2-9) If any of the fiber characteristics were entered incorrectly, press . The user will be asked to repeat
steps 2-3 through 2-7.
F2
Fiber Certification, cont.
SRC PWR
100 m
0 CONN
REF PWR
850nm M6
WAVE
LEN
EDIT
LINK
SAVE
REF.
|
|
|
|
_________________
=
=
=
=
-20.24
-00.38
+00.00
-20.62
2-10) Press to save the reference.
2-11) If the user is testing at an additional wavelength, press . The user will be prompted to connect a light source for the other
F3
F1
3-2
FIBER CERTIFICATIONUNIT 3