Instructions / Assembly
22
Water Storage Tank
NOTE! Do not tamper with the air valve on the lower side of
the Water Storage Tank. It has been preset at 7-10 PSI.
1. Open the Water Storage Tank box and unscrew the Tank Stand
from the threaded em at the top of the Tank.
2. Wrap the threaded em 8-10 times with Teon Tape.
3. Screw the Tank Valve onto the threaded em. Make sure it is
tight, but do not over tighten.
4. Place the Water Storage Tank near the RO Syem in the de-
sired location. The Tank can and up raight or lie on its side.
5. Connect the Yellow Tubing to the Stem Run Tee of the Inline
Po Carbon Filter, then to the Tank Valve (See I to J on Page 23).
6. Keep the Tank Valve in the Closed Position until Syem Startup.
NOTE! If after 3-5 hours your tank does not ll: Connect the tank
directly to the cold water supply (bypassing the RO Syem) and
allow the tank to ll for about 1 minute. Then reconnect to your
syem as normal and empty the tank through faucet. This will
help activate the tank bladder.
NOTE! The Tank Valve only controls
water leaving the Water Storage Tank.
To op all incoming water use the
Feed Water Adapter Valve.
A. Tank Thread
B
A
C
B. Tank Valve
OPEN POSITION
C. Tank Stand
CLOSED POSITION