Use and Care Manual

20
Filter Change Instructions
This Sy󰍰em uses Filters that mu󰍰 be replaced at regular intervals to maintain proper performance.
How to Change the SED, GAC, and ACB
(Recommended about every 6 months)
1. You will need a clean cloth, dish soap, and appropriate
Filters. We also recommend a bucket or bin large enough for
the sy󰍰em to sit in. The sy󰍰em will release water when it is
disassembled.
2. Turn o the Cold Water Supply connected to the Sy󰍰em
(refer to page 11), and the Feed Water Adapter Valve (page
12). Then open the Drinking Faucet handle to release pressure,
close handle when the ow of water 󰍰ops.
3. Place the sy󰍰em in the bucket and unscrew the Filter Housings using the Filter Housing Wrench. Remove
old lters and dispose of them.
4. Wash the Filter Housings with dish soap then proceed to rinse until all soap is removed.
5. Ensure your hands are washed clean before unwrapping the new lters. After unwrapping, place the new
lters inside their correct housings. Make sure the O-Rings are in their proper locations.
6. Tighten the Filter Housings using the Filter Housing Wrench. Do not overtighten. If these are the only
lters you are replacing continue to the Re󰎣arting the Sy󰎣em section on Page 20.
ACB SEDGAC
Restarting The System
1. Fully open the Feed Water Adapter Valve and Cold Water Supply
2. Open the Drinking Faucet handle for 10 minutes before turning the faucet o.
3. Let the sy󰍰em sit for 3 hours.
Be sure to check for new leaks during the r󰎣 24 hours after re󰎣arting
4. Run the drinking water faucet for 10 more minutes.
5. Now your water is ready to drink!
NOTE! If the Sy󰎣em is connected to a refrigerator do not drain the sy󰎣em through the refrigerator
water dispenser. The excess carbon nes from the new carbon lter will clog the internal fridge lter.