Use and Care Manual
17
Leak Stop Valve
Note! Please avoid contact of any liquid to the compressed textile. Failure to do so will activate the
textile and shut the incoming water. Textile will not work if plaic wrap is not removed.
Please do not re-use Leak Stop pads once activated.
4. Take the plaic wrap o of the Compressed
Textile then place the Textile inside the Leak Stop
Valve as shown above. You may wish to insert the
Compressed Textile after Syem Startup is com-
plete in case of early monitored leaks.
INOUT
Flow Closed Position
5. Turn the Stop Switch down and the
Leak Stop Valve is ready.
Red
Tube
White
Tube
INOUT
Flow Open Position
2. Position the Leak Stop Valve on the oor of the same
cabinet beside the syem (so any leaking water will make
contact with the valve) and use the two screws to secure
the Valve to the cabinet oor. Place Leak Stop Valve in the
lowe possible location beside the syem.
3. Connect one end of the Red Tubing into the Feed Water Adapter Valve and connect the other end
of the Red Tubing into the hole marked “IN” on the Leak Stop Valve. Then connect one end of the
White Tubing into the hole marked “OUT” on the Leak Stop Valve and connect the other end of the
White Tubing into the Male Elbow Fitting attached to the Sediment Filter Housing marked “IN”.
Red TubeWhite Tube
INOUT
1. Position the Direct Syem in
the desired permanent location.
Your syem can be placed on its
back for space if needed.