User Manual

Activate Password Protection
In the menu KEY the password protection of the fixture is activated or deactivated. If set ON the
fixture is password protected when started. 30 seconds after the last setting the menu is locked
again. To be able to make changes in the menu the password UP - DOWN - UP - DOWN - ENTER
needs to be typed in.
MENU
MENU
Calibration and Whiteadjustment
In the menu CALIB.C the calibrations and whiteadjustments can be set.
In the submenu WHITE the preset colour temperatures for the white values are stored.
In the menu RGBW a custom colour calibration is stored which limits the maximum brightness of the
colour channels at the DMX value "255".
NOTE: The maximum value can be limited to 0. In this case, a colour channel does not respond
to a sent DMX value, which can be misinterpreted as a device error.
To reset the changes made to the colour temperature presets to factory default, the setting
CALR needs to be confirmed with the default password UP - DOWN - UP - DOWN - ENTER.
E-29
PERSON
HSICKEY
ON
HSIC
OFF
Info Menu
MENU
In the info menu (INFO), submenu VERSION the currently installed firmware version is shown. In the
submenu RDM, submenu UID the RMD-ID of the fixture and in the submenu LABEL the model name
of the fixture can be found.
PERSON
HSIC
INFO VERSION
VXX
HSICRDM
UID
0X3503Axxxxxxx
LABEL
MC 180
PERSON
CALIB.C
WHITE
WHITE.01
2700K
3000K
8000K
WHITE.12
o
o
o
RGBW
R(0 - 255)
G(0 - 255)
B(0 - 255)
o
o
o
WHITE.02
****
****
CALR OK