User Manual

Miscellaneous Settings
MENU
The default password is: UP - DOWN - UP - DOWN - ENTER
UPLOAD: sends the user programs to connected slave fixtures.
RESET: sets all editable settings back to factory default.
COLOR: in this submenu a colour calibration is selected or deactivated. When RGBW is selected,
the maximum brightness values at DMX = 255 are limited to the values set in CALIB.C\RGBW.
When UC is selected the Uniform-Colour factory calibration is used, which adjusts devices of
different generations. If the value is set OFF, the calibration is deactivated and the device reaches
the maximum brightness.
DIMMER: controls different dimming speeds to simulate a halogen bulb (OFF/DIM1/DIM2/DIM3/
DIM4).
DMX ERROR: sets how the fixture responses if DMX-signal gets lost. Set SAVE to hold the last
received value or BLACK for blackout.
PWM: gives the user the possibility to adjust the PWM frequency of the leds (600Hz/1200Hz/2000Hz/
2400Hz/6000Hz/25000Hz).
FULL POWER CCT: sets the colour temperature at maximum output. 3200K/4200K/5600K/ and
NORMAL can be set.
E-28
PERSON
SETTING
HSIC
UPLOAD
****
HSIC
RESET
HSIC
COLOR
HSICDIMMER
HSIC
DMX ERROR
HSICPWM
****
OFF
RGBW
UC
OFF
DIM1
DIM2
DIM3
DIM4
SAVE
BLACK
600HZ
1200HZ
2000HZ
2400HZ
HSIC
****
SEND
RESET
6000HZ
25000HZ
3200K
4200K
5600K
NORMAL
HSIC
FULL POWER CCT