Specifications
10-2
SECURITY
Enhanced Features Arming The System In
“At Home” Mode.
In the ‘at home’ mode, any sensor that is
programmed to be isolated, such as the PIR
sensor will not trigger the alarm. Arm as normal
followed by a second press on the arm/disarm
button within 2 seconds. Normal “on” tone
followed by “at home” tone indicating isolation is
active. There will then be a Settling time of 15
seconds before the alarm responds to any
triggers. Armed in the isolation mode will be
indicated by a double flash intermittently of the
LED. The “at home” sensors will be isolated;
other sensors will trigger the siren for 30
seconds.
Arming the System in Test or Buzz Mode
In the buzz mode the siren will sound a short
tone when a sensor is triggered instead of
sounding for 30 seconds. It is advisable to test all
the sensors.