Specifications

3. Setting the switch when on 12 volt battery
then using mains electric supply (230
volts).
TO ADJUST THE PRESSURE SWITCH:
1. With the system properly primed, close all
taps and showers.
2. Leave the pump run switch (located on the
12 volt distribution panel) turned on.
3. Tighten the adjusting screw clockwise. The
pump should now be running.
4. Partly open one cold tap to allow water to
flow at about 1 pint in 15 seconds.
5. Slowly loosen the adjusting screw, by
turning anti-clockwise, until you can hear
the micro-switch start to click. The
diaphragm will then be properly adjusted.
NOTES
1. Never allow the pump to run DRY.
Always ensure that the pump is
submerged in the water or the life of the
pump will be reduced.
2. Do not allow the pump, the water container
or the water system to freeze in the winter.
Always drain the system at the end of the
season.
3. Clean the water system at the start and the
end of the season with a sterilising fluid,
29
MOTORHOME EQUIPMENT