Specifications
Run
This is the green indicator light. When the
pump switch is on and the pump is running
this light should be on. When the pump is not
running the light should not be on.
Note: this indicator only works with the internal
pump.
Waste
This is the red indicator light. When the
onboard waste tank is becoming full and
requires emptying this light will come on. Once
the tank is empty the light will go out.
TRUMA ULTRASTORE WATER
HEATER
This water heater features a dual source
system of water heating powered by Liquid
Petroleum Gas or 230V mains electricity. For a
faster heating up period the appliance can be
simultaneously operated with gas and
electricity. The holding tank has a capacity of
10 litres.
The system may be fitted to a mains water
supply with special adaptors which include a
pressure reducer which does not allow
pressure to exceed 2.8 bar.
During the initial operation of a brand new
appliance some fumes are normal. These
should soon disperse if the motorhome is well
ventilated.
FILLING THE TRUMA ULTRASTORE
1. Check the safety/drain valve in the cold
water intake is closed. The lever should be
in the horizontal position (e) Fig. C.
2. Set the hot tap in either the washroom or
kitchen in the open position.
3. Switch on the power for the water pump.
4. Leave the tap open to let air escape while
the water heater is filling. The heater is full
when water flows freely from the tap. (See
Connection of Water section.)
5. It may be necessary to adjust the pressure
switch on the water system.
WARNING:
Always fit the cowl cap when the water
heater is not being operated. If there is
any risk of frost and preferably each
time you leave the site, the water heater
should be drained leaving all taps open.
Frost damage is not covered by the
warranty.
23
MOTORHOME EQUIPMENT