User's Manual
16
4” (10cm)
4”
Minimum 3’
from floor
Choosing the Mounting Location in a Room
BEST
Center on ceiling.
ACCEPTABLE
On ceiling, at least 4” (10cm) from intersection
with wall.
ACCEPTABLE
On wall, at least 4” (10cm) from ceiling, and at
least 3 feet (0.9m) from the floor.
Applying the Self-Adhesive Warning Labels
Add the telephone numbers of your emergency
service provider and that of a qualified technician
in spaces provided.
This Heat alarm was shipped with two (2) self-
adhesive Warning Labels.
Place one label next to the alarm, and the other
label near a source of fresh air where your family
plans to gather if the alarm indicates the presence
of Heat .
WARNING
WARNING
Cleaning Your Alarm
Over time, dust might collect within your alarm, potentially reducing its
performance. To clean the alarm perform the following:
Remove the alarm from its bracket.
Vacuum all the external surfaces carefully. Wipe
with a clean, dry cloth. Do not use cleaners or
solvents.
Do not submerge the CO alarm in water.
The sensitive electronics will be damaged!
Press and release the Test button on the front
face to verify the alarm is still functioning prop-
erly and reinstall on the wall/ceiling.
Note: Avoid placement of alarms close to ceiling
fans or heating/air conditioning vents.