User guide

Sales Service Recycling 888.563.6300 in the USA 800.268.2698 in Canada
11
10. FLX200 STANDARD CHARGER OPERATION
CHARGE CONDITION
DISPLAY
DEFAULT
FUNCTION BUTTON DISPLAY SELECTION LED
I1 A A,V,Ah,t,Ph Y*
CONSTANT VOLTAGE A/ #StSt A,V,Ah,t,Ph Y
I2 A A,V,Ah,t,Ph Y
COOL DOWN PERIOD CooL / rt A,V,Ah,t,tr G*
TERMINATION rEdy A,V,Ah,t,tr G
TERMINATION/ FAULT CODE rEdy / F A,V,Ah,T,tr R*, G
REFRESH CHARGE A / rEFr A,V,Ah,t,tr G, Y
SETTING EQUALISE EqAL for 5 seconds then default display
Charge
stage
EQUALISE CHARGE A / EqAL A,V,Ah,t,tr G*, Y
AUTO BALANCE StSt / A StSt / V A,V,Ah,t,tr G
Lobt CHARGE PERIOD Lobt / A A,V,Ah,t Y*
Lobt OFF PERIOD Lobt / V A,V,Ah,t
CRITICAL FAULT CODE F
R
NONE CRITICAL FAULT CODE F Charge continues R*
DELAYED START OF CHARGE dELy / rt
A = Output current
V = Volts per cell
Ah = Returned ampere hours
t = Time of recharge
F = Fault code, display will alternate with the two codes
Ph = Phase of charge i.e. 1, 2 and 3
StSt = Smart start
Cool = Cool down period
LoBt = low battery override
/ = Display will alternate with the two-displayed information
rt = Remaining time
tr = Termination method, tr1 = dv/dt, tr2 = I2 entered 3.5 hour timer operated
tr3 = Constant voltage stage entered 3.5 hour timer operated, tr4 = di/dt.
tr5 = Smart Start, tr6 = Autobalance timeout
* = flashing LED.
NOTE: In LoBt, StSt, Equalise and Termination charge function display will only be displayed for 10 seconds, not
permanently.
# Display if due to smart start.
R: Red = Fault, flashing red is a none critical fault.
Y: Yellow = Current flowing, flashing yellow when < 2.37VPC.
G: Green = charge complete.