Owner's manual

6. CHARGING
The start rate of a fast charge battery can be as high as 40% of the batteries rated
capacity at the 6 hour rate. During the end of the day full charge, the charge rate should
taper down to the finish rate (approximately 5% of the rated capacity) by the time the
battery is 85% charged and may be even lower when the battery is fully charged. Short
running times and/or low end-of-charge specific gravities may indicate inadequate
recharge. Consult your local GNB representative on specific charging problems.
7. MAINTENANCE
KEEP RECORDS… Showing specific gravities, equalizing, charging, temperature,
cleaning and voltages on a monthly basis. These records are required to maintain your
warranty.
TEMPERATURE Under normal fast charge operating conditions, the
electrolyte temperature shall be between 60-140° F. Operating temperature
above 100° F will reduce the battery’s service life. Operating temperature
below 60° F results in less capacity and special charging is required.
WATER ADDITIONS… GNB-approved fast chargers have the capability for equalize
charging at specific times and days of the week (e.g. Sunday 08:00). Water additions can
be made the following day prior to use, provided an equalization charge is confirmed to
have been performed.
EQUALIZE… Once a week.
DEPTH OF DISCHARGE… Do not discharge the battery below 80% of the rated
capacity. Over discharging shortens the battery life and voids the warranty.
CLEANING… Keep the top of the battery clean and dry. See Item 8.
PREVENTIVE MAINTENANCE SCHEDULE…
WEEKLY
Check electrolyte levels (see water additions).
Equalize charge.
MONTHLY
Record electrolyte specific gravities.
• Visual inspection and confirmation that the battery-mounted monitor is
functioning properly.
Inspect the cables and charging plugs.
Clean the top of the cells.
SEMI-ANNUAL
• Inspect the charger. Confirm proper output voltage and current. Check for
external damage, frayed cables, or worn connectors.
Clean the exterior of the battery.