1) From idle, press ‘Enter
Use the arrow keys to enter the First Level
password ‘1111’ and then press ‘Enter’.
2) Use the up and down arrow keys to make
sure the
is next to Alarms and then
press ‘Enter’
3) Use the up and down arrow keys to make
sure the
is next to Link Up Time and
then press ‘Enter’.
4) Use the up and down arrow keys to
choose the required alarm time and then
press ‘Enter’ to accept.
Note that the currently selected option is
indicated by an asterisk.
5) Press ‘Escape’ until the display returns to
idle
4.4.4 Low RSSI Alarm
The user may set an RF level between -40dBm and -110dBm at which the Low RSSI
Alarm will trigger. The Exicom default value is -96dBm. To set this trigger point:
1) From idle, press ‘Enter
Use the arrow keys to enter the First Level
password ‘1111’ and then press ‘Enter’.
2) Use the up and down arrow keys until the
is next to RF Parameters and then
press ‘Enter’
3) Use the up and down arrow keys to
position the
next to RSSI and then
press ‘Enter’.
4) Press the down arrow key then press
‘Enter’.
5) Use the up and down arrow keys to
select the required alarm trigger point,
then press ‘Enter’.
The currently selected setting is indicated
by an asterisk.
6) Press ‘Escape’ until the display returns to
idle